6. TROUBLESHOOTING GUIDE

SYMPTOMS

REASON

REMEDY

Pump does not reach required pressure. Nozzle incorrect or worn.

Replace the lance.

Dirty filter.

Clean or replace filter.

Air being sucked into the system. Check that hoses and fittings are air tight.

Water pressure low.

Check that hoses/fittings are water tight and tap is fully open.

Worn seals.

Contact Authorised Service Agent.

Fluctuating pressure.

Nozzle worn or blocked.

Replace the lance or clear nozzle.

Water too hot.

Reduce temperature.

Pump sucking air.

Check that hoses and fittings are air tight.

Water or oil leaks.

Seals worn.

Contact Authorised Service Agent.

Motor does not start when switched on

No electrical power.

Check plug connections and mains power supply is active.

Automatic cut-off system fault.

Contact Authorised Service Agent.

Motor hums but does not start

Unsuitable mains voltage.

Check for adequate power supply and cable condition.

when switched on.

Motor/pump jammed.

Contact Authorised Service Agent.

Pump frozen.

Leave unit to thaw naturally. The pressure washer should be

protected from the threat of freezing. Extensive pump damage 

could otherwise occur (see end of Section 4).

Incorrect extension cable.

Use a suitable extension cable. 

See Section 1 Elect. Safety.

The motor stops.

Tripped thermal cut-out due to

Check that the mains voltage matches the specifications.

overheating.

Switch off the motor and let machine cool for 5 minutes.

No detergent.

Detergent container is empty.

Refill detergent container.

Detergent pick up body clogged.

Clear blockage.

Injector clogged.

Clean injector.

Jet is ineffective,ragged or unsteady.

Nozzle clogged.

Clean nozzle.

Fuse blows in plug.

Back pressure build up of water

Depress trigger before switching on the machine.

causes machine to draw 

high amperage.

PC1950 - 1 - 190105

Summary of Contents for PC1950

Page 1: ...act a qualified electrician to ensure that a 30 amp supply is available We recommend that you discuss the installation of an industrial round pin plug and socket with your electrician 1 1 11 If an extension reel is used it should be fully unwound before connection A reel with an RCD fitted is preferred since any appliance plugged into it will be protected The cable core section is important and sh...

Page 2: ... cables Use the handle 8 DO NOT touch plug with wet hands To avoid the risk of electrocution keep all connections dry and off the ground 8 DO NOT direct jet against yourself other persons animals electrical equipment or the machine itself 8 DO NOT use washer if you are tired or under the influence of alcohol drugs or intoxicating medication 8 DO NOT allow children or untrained persons to operate t...

Page 3: ... in fig 2 4 2 CONNECTING THE HIGH PRESSURE HOSE Remove and discard the transit plug from the water out connector on the lower front of the machine fig 3 Attach the high pressure hose to the pressure washer fig 4 ensuring that the connector is tight Turn on the water supply 4 3 ASSEMBLING THE LANCE OR DETERGENT DISPENSER Push the lance dispenser onto the gun fig 5 and turn through 90O until it clic...

Page 4: ...r use in pressure washers 5 4 2 Unscrew the detergent bottle from the detergent dispenser 5 4 3 Fill the detergent bottle with soap or wax and screw back onto the detergent dispenser 5 4 4 Attach the detergent dispenser fig 10 5 4 4 The chemical will be automatically mixed with the water and discharged through the nozzle 5 4 5 Dirt is dissolved by applying detergent to the dry surface On vertical ...

Page 5: ...e Agent Motor hums but does not start Unsuitable mains voltage Check for adequate power supply and cable condition when switched on Motor pump jammed Contact Authorised Service Agent Pump frozen Leave unit to thaw naturally The pressure washer should be protected from the threat of freezing Extensive pump damage could otherwise occur see end of Section 4 Incorrect extension cable Use a suitable ex...

Page 6: ...ugged from the mains electrical power supply and turned off at the mains water tap before performing any maintenance tasks 7 1 REGULAR MAINTENANCE 7 1 1 Check clean or renew the inlet filter which is fitted inside the hose connector see contents item 6 after every 50 hours of use 7 1 2 Ensure that both nozzles are kept clean and free of debris 7 1 3 Check unit lance detergent bottle hose connectio...

Page 7: ...logue and promotions call us on 01284 757525 and leave your full name and address including postcode PARTS LIST FOR PRESSURE WASHER 1450PSI MODEL PC1950 Issue 2 Issue Date 130605 KIT PART NO DESCRIPTION 0 PC1950 KIT 0 MAIN ASS Y NOT SHOWN 01 PC1950 KIT 1 MOTOR PUMP ASS Y 02 PC1950 KIT 2 MOTOR COVER ASS Y 03 PC1950 KIT 3 PUMP ASS Y 04 PC1950 KIT 4 PUMP PEDESTAL ASS Y 05 PC1950 KIT 5 THRUST BEARING ...

Reviews: