F R M - 1 0 1 0 I N S T R U C T I O N M A N U A L
11
Operation
Figure 9. Control Panel of FRM-1010
1.
Switch the circuit breaker to the "On" position.
2.
Turn Power, Heater, and Fan switches to the “On” position. Belts and conveyor will begin to move
simultaneously.
3.
Emergency Stop – Press the emergency stop to turn off the machine. In order to restart the
machine, you must release the emergency stop by turning the knob 120˚ clockwise.
4.
Adjust the conveyor speed.
5.
Adjust the temperature controller to the temperature desired to seal your material. Temperature
settings will vary based on bag material and thickness. If you are unsure what temperature setting
to use, we recommend starting at a low temperature (150ºC) and gradually increase to a
temperature that will seal your material. We highly discourage sealing material at a temperature
above 200ºC.
Please note: Temperature will be in Celsius, not Fahrenheit.
The
temperature controller cannot be displayed in Fahrenheit.
The PV value (red light) is the actual temperature and the SV value (green light) is the desired
temperature setting.
Figure 10. FRM-1010 Temperature Controller
Summary of Contents for Impresse FRM-1010
Page 11: ...F R M 1 0 1 0 I N S T R U C T I O N M A N U A L 7 Getting to Know your Band Sealer...
Page 27: ...F R M 1 0 1 0 I N S T R U C T I O N M A N U A L 23...
Page 29: ...F R M 1 0 1 0 I N S T R U C T I O N M A N U A L 25 Figure 36 Spare Parts Diagram Overview...
Page 32: ...F R M 1 0 1 0 I N S T R U C T I O N M A N U A L 28...
Page 33: ...F R M 1 0 1 0 I N S T R U C T I O N M A N U A L 29 Figure 38 Heating Cooling Blocks...
Page 35: ...F R M 1 0 1 0 I N S T R U C T I O N M A N U A L 31 Figure 40 Dry Ink Coding...
Page 37: ...F R M 1 0 1 0 I N S T R U C T I O N M A N U A L 33 Figure 42 Conveyor Table...
Page 40: ...F R M 1 0 1 0 I N S T R U C T I O N M A N U A L 36...
Page 41: ...F R M 1 0 1 0 I N S T R U C T I O N M A N U A L 37 Figure 45 Sealer Body...
Page 48: ......