1.8.3
Relative humidity
Operating
8% to 80% noncondensing
Maximum wet bulb 29.4°C (85.0°F)
Nonoperating
5% to 95% noncondensing
Maximum wet bulb 40.0°C (104.0°F)
1.8.4
Altitude
Operating
–1,000 ft to 10,000 ft (–305 m to 3,050 m)
Nonoperating
–1,000 ft to 40,000 ft (–305 m to 12,200 m)
1.8.5
Shock and vibration
Shock measurements are based on an 11 msec, half sine wave shock
pulse, not to be repeated more than twice per second. The specifications
in the table below are defined as follows:
•
During normal operating shock and vibration, the drive sustains no
physical damage and reads and writes data without errors.
•
During abnormal operating shock and vibration, the drive sustains no
physical damage, but performance is adversely affected.
•
During nonoperating shock and vibration, the read/write heads are in
the shipping zone and the drive sustains no physical damage.
Normal
operating
Abnormal
operating
Nonoperating
Shock
2.0 Gs
10.0 Gs
75.0 Gs
5–22 Hz vibration
0.020-inch
displacement
peak-to-peak
0.030-inch
displacement
peak-to-peak
0.160-inch
displacement
peak-to-peak
22–300 Hz vibration
1.0 G
peak-to-peak
1.5 Gs
peak-to-peak
8.0 Gs
peak-to-peak
1.9
Acoustics
Sound pressure is measured at idle from 1 meter above the drive top
cover.
Sound pressure, typ
29 dBA
Sound pressure, max
33 dBA
8
Medalist XE Family Product Manual, Rev. B