6
will not be obstructed. Adequate clearance for air openings into the
combustion chamber must be provided. Make sure there is an adequate
supply of air in the room to allow for combustion of the gas at the burners.
INSTALLATION CODES AND STANDARDS
Ranges must be installed in accordance with:
In the United States of America:
1. State and local codes.
2. National Fuel Gas Code, ANSI/Z223.1 (latest edition). Copies may be
obtained from The American Gas Association, Inc., 1515 Wilson Blvd.,
Arlington, VA22209.
In Canada:
1. Local codes.
2. CSA B149.1 Natural Gas and Propane Installation Code.
3. CSA C22.1 Canadian Electric Code.
4. CSA C22.2 Canadian Electric Code.
The
above
are
available
from
the
Canadian
Standard
Association,
5060
Spectrum
Way,
Suite
100,
Mississauga,
Ontario,
Canada
L4W
5N6.
ASSEMBLY:
Ranges
Mounted
on
Casters
Ranges
mounted
on
casters
must
use
a
flexible
connector
that
complies
with
the
Standard
for
Connectors
for
Movable
Gas
Appliances,
ANSI-Z21.69
•
CSA
6.16
and
a
quick-disconnect
device
that
complies
with
the
Standard
for
Quick-
Disconnect
Devices
for
Use
With
Gas
Fuel,