background image

12

Limited Warranty

SEAGATE

 

warrants

 

to

 

the

 

original

 

purchaser

 

of

 

new

 

equipment

 

that

 

said

 

equipment,

 

when

 

installed

 

in

 

accordance

 

with

 

our

 

instructions

 

within

 

North

 

America

 

and

 

subjected

 

to

 

normal

 

use,

 

is

 

free

 

from

 

defects

 

in

 

material

 

or

 

workmanship

 

for

 

a

 

period

 

of

 

1

 

year.

 

The

 

labor

 

warranty

 

is

 

one

 

year

 

from

 

original

 

installation

or

 

18

 

months

 

from

 

actual

 

factory

 

shipment

 

date

 

whichever

 

date

 

occurs

 

first.

 

Warranty

 

includes

 

on

 

site

 

service

calls

 

within

 

60

 

miles

 

of

 

an

 

authorized

 

service

 

company.

 

End

 

user

 

is

 

responsible

 

for

 

all

 

extra

 

travel

 

and

 

mileage

 

at

 

prevailing

 

rates.

THIS

 

WARRANTY

 

IS

 

IN

 

LIEU

 

OF

 

ALL

 

OTHER

 

WARRANTIES,

 

WHETHER

 

EXPRESSED

 

OR

 

IMPLIED.

 

SEAGATE

 

EXPRESSLY

 

DISCLAIMS

 

ANY

 

IMPLIED

 

WARRANTY

 

OF

 

MERCHANTABILITY

 

OR

 

EXPRESSED

 

OR

 

IMPLIED

 

WARRANTY

 

OF

 

FITNESS

 

FOR

 

A

 

PARTICULAR

 

PURPOSE.

SEAGATE

’S

 

OBLIGATION

 

AND

 

LIABILITY

 

UNDER

 

THIS

 

WARRANTY

 

IS

 

EXPRESSLY

 

LIMITED

 

TO

 

REPAIRING

 

AND

 

REPLACING

 

EQUIPMENT

 

WHICH

 

PROVES

 

TO

 

BE

 

DEFECTIVE

 

IN

 

MATERIAL

 

OR

 

WORKMANSHIP

 

WITHIN

 

THE

 

APPLICABLE

 

WARRANTY

 

PERIOD.

 

All

 

repairs

 

pursuant

 

to

 

this

 

Warranty

 

will

 

be

 

performed

 

by

 

an

 

Authorized

 

Designated

 

SEAGATE

 

Service

 

Location

 

during

 

normal

 

working

 

hours.

 

This

 

warranty

 

does

 

not

 

cover

 

services

 

performed

 

at

 

overtime

 

or

 

premium

 

labor

 

rates.

 

End

 

user

 

is

 

responsible

 

for

 

the

 

difference

 

between

 

normal

 

service

 

rates

 

and

 

premium

 

service

 

rates.

 

IN

 

NO

 

EVENT

 

SHALL

 

SEAGATE

 

BE

 

LIABLE

 

FOR

 

INCIDENTAL

 

OR

 

CONSEQUENTIAL

 

DAMAGES

 

TO

 

BUYER

 

OR

 

ANY

 

THIRD

 

PARTY,

 

INCLUDING,

 

WITHOUT

 

LIMITATION,

 

LOSS

 

OF

 

PROPERTY,

 

PERSONAL

 

INJURY,

 

LOSS

 

OF

 

BUSINESS

 

OR

 

PROFITS

 

OR

 

OTHER

 

ECONOMIC

 

LOSSES,

 

OR

 

STATUTORY

 

OR

 

EXEMPLARY

 

DAMAGES,

 

WHETHER

 

IN

 

NEGLIGENCE,

 

WARRANTY,

 

STRICT

 

LIABILITY,

 

OR

 

OTHERWISE.

 

This

 

warranty

 

is

 

given

 

only

 

to

 

the

 

first

 

purchaser

 

from

 

a

 

retail

 

dealer.

 

No

 

warranty

 

is

 

given

 

to

 

subsequent

 

transferees.

 

Warranty

 

does

 

not

 

cover

 

product

 

failures

 

caused

 

by:

 

failure

 

to

 

maintain,

 

neglect,

 

abuse,

 

damage

 

due

 

to

 

excess

 

water,

 

fire,

 

normal

 

wear,

 

improper

 

set

 

up

 

and

 

use.

 

Periodic

 

maintenance

 

is

 

not

 

covered.

This

 

warranty

 

is

 

not

 

in

 

force

 

until

 

such

 

time

 

as

 

a

 

properly

 

completed

 

and

 

signed

 

installation/warranty

 

registration

 

or

 

an

 

online

 

registration

 

form

 

has

 

been

 

received

 

by

 

SEAGATE 

within

 

30

 

days

 

from

 

the

 

date

 

of

 

installation.

Proof

 

of

 

purchase

 

is

 

required

 

to

 

extend

 

warranty

 

more

 

than

 

1

 

year

 

from

 

date

 

of

 

shipment

 

from

 

the

 

factory

.

THE

 

FOREGOING

 

WARRANTY

 

PROVISIONS

 

ARE

 

A

 

COMPLETE

 

AND

 

EXCLUSIVE

 

STATEMENT

 

BETWEEN

 

THE

 

BUYER

 

AND

 

SELLER.

 

SEAGATE

 

NEITHER

 

ASSUMES

 

NOR

 

AUTHORIZES

 

ANY

 

PERSONS

 

TO

 

ASSUME

 

FOR

 

IT

 

ANY

 

OTHER

 

OBLIGATION

 

OR

 

LIABILITY

 

IN

 

CONNECTION

 

WITH

 

SAID

 

EQUIPMENT.

Example

 

of

 

items

 

not

 

covered

 

under

 

warranty,

 

but

 

not

 

limited

 

to

 

just

 

these

 

items:

1

2

3

4

5

6

7

8

9

Acts

 

of

 

God,

 

fire,

 

water

 

damage,

 

burglary,

 

accident,

 

theft.

 

Freight

 

damage.

Improper

 

installation

 

or

 

alteration

 

of

 

equipment.

Use

 

of

 

generic

 

or

 

after-market

 

parts.

Repairs

 

made

 

by

 

anyone

 

other

 

than

 

a

 

SEAGATE

 

designated

 

servicer.

Expendable

 

wear

 

parts,

 

adjustable

 

feet,

 

blown

 

fuses,

 

lamps,

 

etc.

 

Cleaning

 

of

 

equipment.

Misuse

 

or

 

abuse.

Summary of Contents for SGR-10-60

Page 1: ...4 SGR 6 36 SGR 10 60 SGR 6B 24MG 60 WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT ...

Page 2: ...INSTALL GAS EQUIPMENT WHO SHOULD PERFORM THE INITIAL FIELD START UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER ...

Page 3: ...52 000 NG 136 000 LP W27 5 X D36 6X H42 3 366 166 SGR 6 36 6 top burner range one 36 oven 36 212 000 NG 190 000 LP W39 5 X D36 6X H42 3 471 214 SGR 10 60 10 top burner range two 36 oven 60 360 000 NG 326 000 LP W63 5 X D36 6X H42 3 764 347 SGR 6B 24MG 60 6 top burner range one 24 top griddle two 36 oven 60 306 000 NG 272 000 LP W63 5 X D36 6X H42 3 817 371 ...

Page 4: ...nge will result in many years of satisfactory performance suggests that you thoroughly read this entire manual and carefully follow all of the instructions provided Orifice size BTU Description Pressure BTU per burner Orifice size Top burner 5 NAT 24 36 6 NAT 60 30 000 41 10 LP 27 000 53 Oven 5 NAT 24 36 6 NAT 60 32 000 38 10 LP 28 000 53 Top griddle 5 NAT 24 36 6 NAT 60 30 000 39 10 LP 27 000 50 ...

Page 5: ...e all shipping wire and wood blocking Before installing check the type of gas supply natural or propane to make sure they agree with the specifications on the rating plate located on the inside of the lower kick panel If the supply and equipment requirements do not agree do not proceed with the installation Contact your dealer or company immediately LOCATION The appliance must be installed under a...

Page 6: ...rican Gas Association Inc 1515 Wilson Blvd Arlington VA22209 In Canada 1 Local codes 2 CSA B149 1 Natural Gas and Propane Installation Code 3 CSA C22 1 Canadian Electric Code 4 CSA C22 2 Canadian Electric Code The above are available from the Canadian Standard Association 5060 Spectrum Way Suite 100 Mississauga Ontario Canada L4W 5N6 ASSEMBLY Ranges Mounted on Casters Ranges mounted on casters mus...

Page 7: ...hipped with the casters using these screws Fig 1 Attach the gas line strain relief to the tie down strap at the rear of the range Fig 1 If disconnection of the restraint is necessary turn off the gas supply before disconnection Reconnect this restraint prior to turning the gas supply on and returning the range to its installation position Separate instructions for installing casters to the range a...

Page 8: ... The standard Restaurant Range is equipped with a 23 584 mm high backsplash and shelf 1 Remove the backsplash components from the crating materials 2 Assemble the required components as shown in Fig s 2 and 3 and 4 ...

Page 9: ...9 3 Tighten the four screws to secure the shelf 4 Lift the assembly up sliding the channels into the space provided at the rear of the range Fig s 5 Fig 2 Fig 3 Fig 4 ...

Page 10: ...10 5 Install four 10 sheet metal screws 2 to each channel leg Fig 6 LEVELING Fig 5 Fig 6 ...

Page 11: ...ply Make sure the pipes are clean and free of obstructions Codes require that a gas shutoff valve be installed in the gas line ahead of the range Standard ranges are equipped with fixed burner orifices which coincide with installation elevation Install the gas pressure regulator Before installing ensure that regulator supplied agrees with rating plate gas supply The gas pressure regulator is NOT f...

Page 12: ... Do not obstruct leak limiter on gas pressure regulator as obstruction may cause regulator to malfunction WARNING PRIOR TO LIGHTING CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS USE SOAP AND WATER SOLUTION DO NOT USE AN OPEN FLAME After piping has been checked for leaks all piping receiving gas should be fully purged to remove air Before operation verify thermocouple is securely seated in the ...

Page 13: ...low of flue gases from the flue located on the rear of the range It is recommended that the flue gases be ventilated to the outside of the building through a ventilation system installed by qualified personnel From the termination of the flue to the filters of the hood venting system a minimum clearance of 18 457 mm must be maintained Information on the construction and installation of ventilating...

Page 14: ...try to knock off loose food that may be on the spatula by tapping the corner edge of the spatula on the griddle surface A new griddle surface must be seasoned to do a good cooking job The metal surface of the griddle is porous Food tends to get trapped in these pores and stick therefore it is important to season or fill up these pores with cooking oil before cooking Seasoning gives the surface a s...

Page 15: ...ot fails to light turn main gas supply OFF Wait 5 minutes and repeat the above procedures 4 Turn one hot top or griddle top burner valve ON to remove air from the gas line Turn burner valve OFF when gas begins to flow Nightly Shutdown 1 Turn burner valve OFF pilot will remain lit Complete Shutdown 1 Turn burner valve OFF pilot will remain lit 2 Turn main gas supply OFF Thermostat GRIDDLE 1 Turn ma...

Page 16: ...or 7 If pilot fails to light turn main gas supply OFF Wait 5 minutes and repeat the above procedures 8 Turn one hot top or griddle top burner valve ON to remove air from the gas line Turn burner valve OFF when gas begins to flow 9 Nightly Shutdown 10 Turn burner valve OFF pilot will remain lit 11 Complete Shutdown 12 Turn burner valve OFF pilot will remain lit 13 Turn main gas supply OFF ...

Page 17: ... turn main gas supply OFF Wait 5 minutes and repeat the above procedures 4 Turn one open top burner valve ON to remove air from the gas line Turn burner OFF when gas begins to flow Nightly Shutdown 1 Turn burner valve OFF pilot will remain lit Complete Shutdown 1 Turn burner valve OFF pilot will remain lit 2 Turn main gas supply OFF ...

Page 18: ...as supply OFF STANDARD OVEN LIGHTING AND SHUTDOWN INSTRUCTIONS NOTE Light open top griddle pilots before lighting oven pilot 1 Turn thermostat to the OFF POSITION 2 Remove the lower panel 3 Depress the red button on the safety valve and light the pilot through the observation area 4 Hold down the red button for at least 30 seconds 5 When button is released pilot should remain lit 6 Replace lower p...

Page 19: ...rd PREHEATING Standard Oven Turn thermostat control to the desired cooking temperature and preheat oven for 25 minutes To save on gas consumption do not operate oven at maximum heat when it is not necessary Turn thermostat down to 250 F 121 C or OFF when oven is not in use or during idle cooking periods Griddle optional models Turn the three manual gas valve knobs to full ON After preheating for 5...

Page 20: ...ontact supplier When calling for service the following information must be available model number serial number manufacture date MD and voltage optional models SEAGATE GAS RESTAURANT RANGES We all recognize however that replacement parts and occasional professional service may be necessary to extend the useful life of this unit When service is needed contact a RANGE Authorized Service Agency or yo...

Page 21: ...P orifice hotplate 4 6 Brass reducing nipple for Range Oven 5 FS 302220059 6 Manual gas valve A18 6 FS 302220027 3 Pilot Valve AP6 for Hotplate 7 FS 03B00050 1 Oven thermostat 8 FS 03600125 1 Safety valve 9 1 Oven orifice 10 FS 309020069 1 Regulator for 4 6 burner range 11 FS 03900080 1 Oven thermopile 12 FS 03510036 1 Oven pilot bracket 13 FS 302250035 1 Oven burner 14 1 Oven pilot tube ...

Page 22: ...ription 1 FS 100105 1 6B back splash 2 1 Shelf board 3 1 Front table 4 FS 301110405 6 Knob 5 FS 03900267 1 Oven thermostat knob 6 FS 100103 1 Oven door 7 2 Oven door hinge 8 FS 4000391 1 Oven radiant plate 9 FS 2660002 4 Caster set for 36 range ...

Page 23: ...g c Improper thermostat bypass setting d Thermostat out of calibration e Fluctuating gas pressure 2 Uneven bake side to side a Not level side to side b Oven burner bottom or baffles improperly installed c Warped pans 3 Uneven bake front to rear a Overactive flue b Not level front to back check casters and legs c Door not closing properly 4 Dried out products a Too low temperature overcooking b Too...

Page 24: ...ing top burner valves b Poor door fit c Oven door left open d improper use of excessively large pans or pots 2 Poor ignition a Insufficient input b Poor air gas adjustment c Restriction in pilot orifice d Restriction in main burner ignition port ...

Page 25: ...ntenance 1 Remove the grate 2 Remove the top burner 3 Screw out top burner air shutter screw 5 Remove orifice 6 Replace the orifice b 4 Adjust air shutter from half open to full open then screw in ensure fix well WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the authority ...

Page 26: ...alf open to full open then screw in ensure fix well 13 1 Regulator conversion Before installing the included convertible regulator unscrew the octagon cap You can read NAT on the plastic insert attached to the head of the cap flip it over and snap back in place Note Unit Number on side of orifice fittings 10 Screw out oven burner air shutter screw 12 Replace orifice and oven burner ...

Page 27: ...rsion label on appliance the position below Gas conversion label The position for gas conversion 16 Completed gas conversion Pictured is the plastic insert Pull off insert from octagon cap and reverse the plastic insert position so that the L P position is attached to the octagon cap head L P Position of insert Regulator is now converted to L P ...

Page 28: ...DENTAL OR CONSEQUENTIAL DAMAGES TO BUYER OR ANY THIRD PARTY INCLUDING WITHOUT LIMITATION LOSS OF PROPERTY PERSONAL INJURY LOSS OF BUSINESS OR PROFITS OR OTHER ECONOMIC LOSSES OR STATUTORY OR EXEMPLARY DAMAGES WHETHER IN NEGLIGENCE WARRANTY STRICT LIABILITY OR OTHERWISE This warranty is given only to the first purchaser from a retail dealer No warranty is given to subsequent transferees Warranty do...

Reviews: