DAT Autoloader Installation Manual
External dip-switches
Figure 3 shows the locations of and default settings for the 10
dip switches on the top of the autoloader. These configuration
options are described in greater detail below.
Figure 3. Location of 10 dip switches on top of internal
autoloader
Block of 10 dip switches
S2
S3
S4
S5
S6
S7
S8
OFF
ON
OFF
SCSI ID
0
1
2
3
4
5
6
7
S9
S10
Default settings:
Reserved
(do not use)
Reserved
Data
compression
Self-test
Parity
MRS
Mode
Enable
Disable
Disable
Enable
Enable
Disable
Enable
Disable
SCSI ID Selection
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
S1
ON
SCSI ID: Switches 1, 2, and 3 (the SCSI-ID bit switches) are
used to select the SCSI ID used by the drive, as shown in
Figure 3. You must select a SCSI ID that is not used by any
other devices on the SCSI bus.
➤
Note. In some computers the SCSI ID 0 (the autoloader’s
default setting) may be used by the bootable hard drive.