Spinpoint M8U-Internal Product Manual REV 3.4
89
INSTALLATION
6.4.3.1 Command Block Wrapper (CBW)
The CBW (Table 6-26) shall start on a packet boundary and shall end as a short packet with exactly 31 (1Fh)
bytes transferred. Fields appear aligned to byte offsets equal to a multiple of their byte size. All subsequent
data and the CSW shall start at a new packet boundary. All CBW transfers shall be ordered with the LSB
(byte 0) first (little endian). Refer to the
USB Specification
Terms and Abbreviations for clarification.
Table 6-26: Command Block Wrapper
dCBWSignature:
Signature that helps identify this data packet as a CBW. The signature field shall contain the value
43425355h (little endian), indicating a CBW.
dCBWTag:
A Command Block Tag sent by the host. The device shall echo the contents of this field back to the host in
the
dCSWTag
field of the associated CSW. The
dCSWTag
positively associates a CSW with the
corresponding CBW.
dCBWDataTransferLength:
The number of bytes of data that the host expects to transfer on the Bulk-In or Bulk-Out endpoint (as indicated
by the
Direction
bit) during the execution of this command. If this field is zero, the device and the host shall
transfer no data between the CBW and the associated CSW, and the device shall ignore the value of the
Direction
bit in
bmCBWFlags
.
bmCBWFlags:
The bits of this field are defined as follows:
Bit 7
Direction
- the device shall ignore this bit if the
dCBWDataTransferLength
field is zero, otherwise:
0 = Data-Out from host to the device,
1 = Data-In from the device to the host.
Bit 6 Obsolete. The host shall set this bit to zero.
Bits 5..0 Reserved - the host shall set these bits to zero.
bCBWLUN:
The device Logical Unit Number (LUN) to which the command block is being sent. For devices that support
multiple LUNs, the host shall place into this field the LUN to which this command block is addressed.
Otherwise, the host shall set this field to zero.
bCBWCBLength:
The valid length of the
CBWCB
in bytes. This defines the valid length of the command block. The only legal
values are 1 through 16 (01h through 10h). All other values are reserved.