background image

Revision 2012.02.27 

1

 

 

 

g{x cÜxÅ|âÅ VÉÄÄxvà|ÉÇ 

 

Ambient and Refrigerated models 

 

 
 

SERVICE and PARTS MANUAL 

 
 
 
 

                       

 
 

 

 

 

 

700 Seaga Drive, Freeport, IL 61032, U.S.A.      visit: seagamfg.com     email: [email protected]

 

 

 

Summary of Contents for SP 430D

Page 1: ...Revision 2012 02 27 1 g x c x V xv Ambient and Refrigerated models SERVICE and PARTS MANUAL 700 Seaga Drive Freeport IL 61032 U S A visit seagamfg com email info seagamfg com...

Page 2: ...sist you in this process in any way possible Feel free to contact our Customer Care Department with questions you may have on this process It is important that you keep the original packaging for your...

Page 3: ...300 Grms Shipping Weight 470 lbs 703 lbs 698 lbs 528 lbs 764 lbs 721 lbs UK Version 220 V Specifications 4 Wide 5 Wide SP 432 F Ambient SP 430D F Refrigerated SP 735R F Refrigerated SP 540 F Ambient...

Page 4: ...ys 6 Standard ENVIRONMENT Location Environment Indoors only ELECTRICAL REQUIREMENT US version requires one 1 120 VAC 12 Amps grounded outlet UK version requires one 1 220 VAC 12 Amps grounded outlet S...

Page 5: ...ling legs if necessary for proper level both side to side and front to back A good point to keep in mind is the shorter the leveling legs are kept to achieve proper leveling the more stable the machin...

Page 6: ...r and to insure proper vending operation Fig 3 Interior View Fig 4 SECTION 2 INSTALLATION CAUTIONS Control Board and Brown Service Mode Button Red Main Power Switch Display Board Door Wire Harness Ref...

Page 7: ...Different countries may have different power arrangements Insure that the machine is properly grounded before operating CAUTION If the power cord is damaged it must be replaced by the manufacturer au...

Page 8: ...in the cabinet by aligning the wheels in the guide rails Clear the wire harness To the side so that it is not interfering with the tray below To increase the length of the Helix Coil white plastic Pro...

Page 9: ...your machine carefully wrapped and inserted into the cabinet Product stabilizers are not absolutely necessary but do assist the product in several ways 1 They present the product in an upright manner...

Page 10: ...hat controls the refrigeration system ON and OFF condition When the door is opened the door switch is not depressed and the refrigeration system shuts OFF When the door is closed the switch is activat...

Page 11: ...ypad Four Service mode Button of keypad Navigation of the Service Mode Menu Button Definition Button This key is used to increase a numeric value or move forward through the various service mode funct...

Page 12: ...ler will beep twice and the display will change to show Service Menu on the first line and Prices on the second line Fig 11 At this time you can use the keypad on the front of the machine to move thro...

Page 13: ...l revert to sales mode Service mode MENUS The chart below shows the sub menus while in Service mode PRICES SUB MENU The Prices sub menu allows you to set prices in three different ways Set ALL Set ONE...

Page 14: ...The Diagnostics menu is used to test various features of the machine Certain critical features of the machine are protected by a pass code provided to the operator to prevent inadvertent modification...

Page 15: ...Temps 2 10 Passcode Tests the components connected via Relays ON OFF Tests the status ON OFF 2 DOOR SWITCHES Clears all errors Display Temperatures of Zone 1 and Zone 2 Display edit the PassCode PASS...

Page 16: ...vends on that individual selection Displays Total Amount of Bills inserted during transactions Displays Total Amount of Card Transaction 4 Settings 4 1 Clock 4 3 Lockout expiry 4 1 2 Date Set Day of t...

Page 17: ...coins of each denomination being inserted Manual Dispense of the Coin mech is enabled in this menu option Fig 12 Depending on the model of changer installed the amount will vary 4 9 2 Bill Reader 4 9...

Page 18: ...the machine to Lock Out Use the Clear Errors function to remove Lock Out status 5 3 Language Bills ON OFF Select the Language 5 13 Passcode 5 4 Health Safety ON OFF 5 5 Temp Zone 1 5 6 Temp Zone 2 5 7...

Page 19: ...stallation i Installation of Card Reader Drivers Either Insert the CD into the CD ROM drive Select the Install Card Reader Driver option Or Windows XP Vista only Insert the CD into the CD ROM drive Pl...

Page 20: ...Guide Hyperlink to www seagamfg com smartware Seaga Smartware Guide pdf Exit close the utility programme Card Status shows the status of the card reader No card inserted Read and Write Card buttons d...

Page 21: ...ck this option and enter a Vend Count value to allow a free selection every Vend Count vends Satellite Machine n check the box to allow the VMC to work with the corresponding Satellite machine When a...

Page 22: ...rresponding price box To set ALL the prices to the same amount enter the amount in the ALL Price box and click the Set All Prices button The VMC can hold prices for the Main Machine and also up to thr...

Page 23: ...ICES PAGE continued Discount Prices Select Discount Prices using the Price Bank pull down The VMC can operate at discounted prices between the Discount Start Time and Discount End Time points refer to...

Page 24: ...The Meal Deal price is charged to the customer and multiple products are vended as specified Each of the 10 meal deals can have an individual price followed by a list of selections that make up the d...

Page 25: ...umber of Decimal Places to be displayed If the required currency symbol is not in the options choose Custom and type in two characters in the Custom Symbol box Date Style Choose between mm dd yy and d...

Page 26: ...ptied manually Bill Reader Check the Enabled box to allow the corresponding Bill to be accepted Check the Use Escrow box to hold the Bill for change and the High Security box to use the corresponding...

Page 27: ...f one selection is sold out the product can be dispensed from another selection This is particularly useful for increasing the effective stock for Meal Deals and for Can Bottles operation In the examp...

Page 28: ...up to 5 direct single button selections For capacity the Space To sales links allow multiple internal spirals to stock the same product In the above example Hot Button 1 selects effectively Tray A The...

Page 29: ...lection Names This window displays the text that is displayed for each Selection or Meal Deal To Edit the Selection Names use the Save to File button to save the text to a particular file This file ca...

Page 30: ...corresponding tray Please note that some older VMC software versions may not support individual use of the Positive Vend Sensor Timings Selection Timeout is the number of seconds for which a selection...

Page 31: ...ks in 0 5C steps so exact Fahrenheit figures may be adjusted to the nearest 0 5C step Auto Defrost Check the box to turn automatic defrosting ON The defrost cycle is run for Defrost Duration minutes e...

Page 32: ...faults button to clear the events back to the factory default configuration Events 1 4 are backwards compatible with earlier versions of VMC software Events 1 and 2 Timed Lockouts with shared Days of...

Page 33: ...ratures are in Centigrade defrost duration is in minutes Readings are logged approximately every minute Appendix 1 File formats Both Audit and Temperature Logging Cards are saved to csv comma separate...

Page 34: ...customer inserts money and enters their selection on the Keypad The selection s Driver Motor turns the Helix Coil that vends the product into the Delivery Bin PRODUCT TRAYS The SP Series features loc...

Page 35: ...may want to consider turning off your sensing system in case of malfunction via product size See the Service Mode section of this manual Diagnostics sub menu for instructions The Vigilant sensors are...

Page 36: ...ons will require a software update Contact your distributor or sales person for update information Q My machine will not take in bills but accepts change ok A Several options here but the most common...

Page 37: ...mp Slo Blo fuse Nothing less An easy way to test the fuse is to press on the lower door switch to see if the 3 evaporator fans run that are located below the bottom tray 3 Inspect the evaporator coil...

Page 38: ...ABINET 2 8428008 ELECTRICAL PANEL ASSEMBLY 3 8428003 DOOR SUPPORT ASSEMBLY 4 7011014 LEG LEFT 5 7021032A LEVELLING SCREW 6 8411002 LEG EXTENSION 7 7011006 LEG RIGHT 8 8428004 GRILL CABINET BOTTOM 9 86...

Page 39: ...18005 TEMPERATURE SENSOR 5 8428016 REFRIGERATION DECK COVER ASSEMBLY 6 8417003 COMPRESSOR 7 8411024 REFRIFERATION DECK TRAY 8 8428017 CAPACITOR BOX ASSEMBLY 9 8411025 CONDENSER FAN HOUSING 10 7017004...

Page 40: ...on 2012 02 27 40 Product Bin Assembly Parts List ITEM PART NO DESCRIPTION 1 7028014 PRODUCT BIN 2 7014014 PUSH DOOR ASSEMBLY 3 8611007 CAM PLATE 4 7011032 PRODUCT GUIDE BRACKET 5 7011033 ANTI THEFT BR...

Page 41: ...DESCRIPTION 1 8411017 ELECTRIC PANEL 2 8418003 TRANSFORMER 110V 220V 1 5A 3 7018012 FILTER 4 7018039 RELAY 24V DC 5 7018032 CIRCUIT BREAKER 6 8411018 SWITCH BRACKET ELECTRICAL PANEL 7 8418006 AUXILAR...

Page 42: ...T SIDE 2 7014024 SENSOR SHEET 3 6014015 SPACER 4 7011041 SENSOR BRACKET RIGHT SIDE 5 8618009 VEND SENSOR DETECTOR Vigilant Vend Sensor Left Side Assembly Vigilant Vend Sensor Left Side Parts List ITEM...

Page 43: ...ed service repair alteration or disassembly has been performed Any defects caused by improper power source poor water quality or pressure an installed water filtration system not fully functioning abu...

Reviews: