Website: www.seada.co.uk
32 / 47
E-mail: [email protected]
4.2.5 Network configuration
1) Network port
Port Data:
set the data port, the device will restart automatically after changed (default 3000,0-65535 optional).
Port Web
: Set Web port, the device will restart automatically after changed (default is 80,0-65535 is optional).
Port Onvif
: Set Onvif port, the device will restart automatically after changed (default 2000,0-65535 optional).
Port Soap
: Set Soap port (default 1936,0-65535 optional).
Port RTMP:
Set RTMP port (default 1935,0-65535 optional).
Port RTSP
: Set RTSP port, the device will restart automatically after changed (default 554,0-65535 optional).
Port Visca
: Set Visca port, the device will restart automatically after changed (default 3001,0-65535 optional).
Click on the "Save" button, it will be valid when display "Save successful".
RTMP access:
RTMP: / / equipment IP address: 1935 / live/av0 (av0 mainstream; av1 second stream)
RTMP Access
:
rtmp://
equipment IP address: 1935 / live/av0 (av0 mainstream; av1 second stream)