background image

GENERAL SAFETY INFORMATION 

An  appliance  shall  be  provided  with  an  instruction  manual.  The  instruction  manual  shall  give  instructions  for  the 
installation, operation, and user maintenance of the appliance.
The installation instructions shall specify the need for a grounding-type receptacle for connection to the supply and 
shall stress the importance of proper grounding.
The installation instructions shall inform the installer that permanent wiring is to be employed as required by local 
codes, and instructions for conversion to permanent wiring shall be supplied.

Information shall be supplied with a gate operator for:

a) The required installation and adjustment of all devices and systems to effect the primary and secondary protection 
against entrapment (where included with the operator).
b)  The  intended  connections  for  all  devices  and  systems  to  effect  the  primary  and  secondary  protection  against 
entrapment. The information shall be supplied in the instruction manual, wiring diagrams, separate instructions, or the 
equivalent.

Vehicular gate operators (or systems)

A vehicular gate operator shall be provided with the information in the instruction manual that defines the different 
vehicular gate operator Class categories and give examples of each usage. The manual shall also indicate the use for 
which the particular unit is intended as defined in Glossary, Section 3. The installation instructions for vehicular gate 
operators shall include information on the Types of gate for which the gate operator is intended.

A gate operator shall be provided with the specific instructions describing all user adjustments required for proper 
operation of the gate. Detailed instructions shall be provided regarding user adjustment of any clutch or pressure relief 
adjustments provided. The instructions shall also indicate the need for periodic checking and adjustment by a qualified 
technician of the control mechanism for force, speed, and sensitivity.

Instructions for the installation, adjustment, and wiring of external controls and devices serving as required protection 
against entrapment shall be provided with the operator when such controls are shipped with the operator.

Instructions regarding intended installation of the gate operator shall be supplied as part of the installation instructions 
or as a separate document. The following instructions or the equivalent shall be supplied where applicable:

IMPORTANT INSTALLATION INSTRUCTIONS

a) Install the gate operator only when:

1) The operator is appropriate for the construction of the gate and the usage Class of the gate,
2) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet 

(1.22 m) above the ground to prevent a 2-1/4 inch (57.2 mm) diameter sphere from passing through the openings 
anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position,

3) All exposed pinch points are eliminated or guarded, and
4) Guarding is supplied for exposed rollers.

b) The  operator  is  intended  for  installation  only  on  gates  used  for  vehicles.  Pedestrians  must  be  supplied  with  a 
separate access opening. The partial access opening shall be designed to promote pedestrian usage. Locate the gate 
such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.

c) The  gate  must  be  installed  in  a  location  so  that  enough  clearance  is  supplied  between  the  gate  and  adjacent 
structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access 
areas.

d) The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. Do 
not over-tighten the operator clutch or pressure relief valve to compensate for a damaged gate.

e) The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving and 
AWAY FROM THE GATE PATH PERIMETER.

f) Controls intended for user activation must be located at least six feet (6’) away from any moving part of the gate and 
where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or 
easily accessible controls shall have a security feature to prevent unauthorized use.

g) The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not 
cause the operator to start.

h) A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible

Summary of Contents for TAURUS BOX 1000

Page 1: ...TAURUS BOX 1000 REV 03 09 2020 SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Toll Free 800 689 4716 www sea usa com 67411390...

Page 2: ...ildren to play or stay within the path of the moving gate 9 Keep remote control or any other control devices out of the reach of children in order to avoid possible involuntary activation of the gate...

Page 3: ...tor Instructions regarding intended installation of the gate operator shall be supplied as part of the installation instructions or as a separate document The following instructions or the equivalent...

Page 4: ...ll provide warning notices on not assessable further risks SEA USA Inc in its relentless aim to improve the products is allowed to make whatsoever adjustment without giving notice This doesn t oblige...

Page 5: ...objact closer than 16 inches 406mm are not required to be provided with a means of entrapment protection B1 and B2 means of entrapment protection MUST be MONITORED HORIZONTAL SLIDE VERTICAL LIFT VERT...

Page 6: ...ent fig 11 GATEARRANGEMENT The first thing to check is that the gate is in good running order as follows a The gate is rigid and straight and runs smoothly throughout its travel b That the inferior sl...

Page 7: ...supply Power Absorbed current Thrust force Capacitor Leaf speed pinion Z17 Use rate Thermal protection Max gate weight Max gate opening Type of limit switch Operating temperatures Operator weight Prot...

Page 8: ...the gate from derailment Fig 16 4 TYPE OF INSTALLATION 3 TYPICAL INSTALLATION 1 Operator 2 Concrete to build operator on 3 Photocells 4 Safety edge 5 Key switch 6 Travel gate stops 7 Radio receiver 8...

Page 9: ...d in that portion of the adjacent fence that the gate covers in open position 5 5 Follow the local building code to determine the required depth of the concrete pad 5 6 SEArecommend the following pad...

Page 10: ...ain with the provided tie rod Fig 22 Fig 22 Fig 23 7 2 Install the chain making it pass through the pinion group as in Fig 24 The chain must be always in line both vertically and orizontally if not pe...

Page 11: ...nal screw the limit switch casing 8 4 To install and adjust the limit switches in opening release the operator open the gate manually act on the adjusting screw so that the microswitch can activate th...

Page 12: ...ys switch off the main power 120V before servicing the operator RELEASE Fig 30 Fig 31 Fig 32 Fig 33 SEA recommend to release the operator only in case of power failure Always contact a pro fessional i...

Page 13: ...TING Fig 34 Fig 37 Fig 38 Fig 39 Fig 36 Fig 35 Note The antenna must be connected on the clamps 1 and 2 of the control unit CN1 connector For further information on the antenna wiring diagram please r...

Page 14: ...arantee will be void and the manufacturer responsability will be nullified if SEAUSAInc original spare parts are not being used The electrical installation shall be carried out by a professional techn...

Page 15: ...l be refused Customers must contact SEAfor instructions WARRANTY for the original buyer only Hydraulic and oil bath motors 36 months warranty from the date of invoice on manufacturing assembling and w...

Page 16: ...SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Toll Free 800 689 4716 www sea usa com sales sea usa com...

Reviews: