PERIODICAL MAINTENANCE  

To the attention of users and technicians 

RELEASE SYSTEM

To release operate as follows:

open the lock cover, insert the key, turn it about  90° clockwise (see  Fig. 26) and open the lid.
Take the red key located under the lid, insert it and turn it about 90° anti-clockwise  (see Fig. 27).

To relock the operator do as follows:

turn the red key clockwise until it stops (see Fig. 27), remove it, put it under the lid 

and close the lid again. 

Attention: Turning the key over 1 turn (360°) could damage the release.

Turn the key anti-clockwise to tighten the lid, remove the key and close the lock cover.

Fig. 26

Fig. 27

Open

Close

Release

Lock

Check the robustness and the stability of the gate; especially the supports and 
the leaning and/or rotation points of the gate (pivots)

Check the oil level in hydraulic / oil-bath operators 
(cap on the back cover of the operator)

Replace the oil with that recommended by the producer

Check the release system functionality

Check and grease the fixation pivots

Check the integrity of the connecting cables

Check the good status of all the apparatus which are subject to efforts 
(back fixation, oscillating fork and front fixation)

Check the functionality of all the accessories especially the function of 
all security devices

After having executed the periodical maintenance it is neccessary to repeat 
the tests and the first power up of the automation

All the above mentioned operations must be executed 

by an authorised installer only

Lubricate the shaft using SEA grease (GREASE GL 00  code 65000009)

Annual

Annual

4 years

Annual

Annual

Annual

Annual

Annual

Annual

Annual

1

2

3

4

5

6

7

8

9

10

11

Annual

Check the by-pass valves functionality

WARNING:  SEA  recommends  to  the  end  user  to  release  the  operator  only  in 
case  of  power  failure  or  after  having  switched  off  the  electric  power.  Always 
contact  a  professional  installer  in  case  of  not  correct  working  of  the  operator

WARNING: 

Always switch off the main power (110V or 230V) before servicing the operator

International registered trademark n. 2.777.971

Summary of Contents for SUPER FULL TANK 500 G6 120V

Page 1: ...it 160 DORAL MIAMI Florida FL 33172 USA Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 web site www sea usa com e mail sales sea usa com REV 02 11 2018 International registered tradema...

Page 2: ...danger 8 Do not allow children to play or stay within the path of the moving gate 9 Keep remote control or any other control devices out of the reach of children in order to avoid possible involuntary...

Page 3: ...ng intended installation of the gate operator shall be supplied as part of the installation instructions or as a separate document The following instructions or the equivalent shall be supplied where...

Page 4: ...es on not assessable further risks SEA USA Inc in its relentless aim to improve the products is allowed to make whatsoever adjustment without giving notice This doesn t oblige SEA to up grade the past...

Page 5: ...to move toward a rigid objact closer than 16 inches 406mm are not required to be provided with a means of entrapment protection B1 and B2 means of entrapment protection MUST be MONITORED HORIZONTAL S...

Page 6: ...the whole movement of the leaf PRECAUTIONS SEA motors have been created for the automation of gates used by vehicles only Be aware to avoid the crossing of the gate path because it is very dangerous f...

Page 7: ...feet or installations in windy places or in case of closed paneled gates SEArecommends the use of the electric lock on operators without block SB moreover the exclusion of electronic slowdown is recom...

Page 8: ...8 Clevis Attachment Front bracket Shaft Cover End cover Shaft Rear attachment Breather screw Pin rear attachment short Brass Pin long Oil fill in cover By pass valves Fig 4...

Page 9: ...cells 11 Warning notice TYPE OF INSTALLATION It is possible to install the Super FullTank with opening inside Fig 6 I n s t a l l t h e operator always i n s i d e t h e p r o p e r t y inside Outside...

Page 10: ...3 39 8 07 8 46 7 87 8 27 7 68 7 68 7 48 7 28 6 69 7 09 6 50 6 30 6 69 5 91 5 51 5 12 3 15 4 72 3 35 4 92 3 94 5 51 5 71 4 72 6 30 4 92 6 50 6 69 5 51 7 09 7 48 7 87 110 90 110 90 105 90 90 102 90 102...

Page 11: ...If you have to make a n i c h e o b s e r v e t h e dimensions shown in Fig 8 RELEASE MOUNTING Remove the transporting plate as shown in Fig 9 Mount the release as shown in Fig 10 a d b 70 87 2 56 2 5...

Page 12: ...nd clevis attachment must be done by the simple pressure of the hands Attention Do not incline the hydraulic operator further than the allowed angle of the oscillating bracket 1 risks the possible bra...

Page 13: ...t in the closed position execute the following operations 1 Release the operator 2 Pull out completely the chromate shaft and push it back in 0 4 inches 3 Attach the shaft to the front bracket Fig 14...

Page 14: ...ASE 3 W 4 5 MOTOR HEATING DETECTOR CONTACT NC 6 GROUND YELLOW GREEN GV 1 2 3 4 5 6 Fig 19 ATTENTION It is obligatory to remove the breather screw at the end of the installation BREATHER SCREW Unscrew...

Page 15: ...s e i n p g O Grey Yellow INSTALLATION OF THE CHROME PLATED SHAFT COVER TORQUE ADJUSTMENT by pass valves Grey Yellow Adjust the opening and closing forces of the gate so that the diagram of the force...

Page 16: ...sured with the rod inserted into the actuator and the oil level must be at the distributor level Fig 25 OIL LEVEL DISTRIBUTOR LEVEL DISTRIBUTOR PHOTOCELLS TRANSMITTER KEY SWITCH RADIO RECEIVER FLASHIN...

Page 17: ...Check the release system functionality Check and grease the fixation pivots Check the integrity of the connecting cables Check the good status of all the apparatus which are subject to efforts back fi...

Page 18: ...ONSIBLE FOR ANY DAMAGE OR INJURY CAUSED BYIMPROPER USE OF THIS PRODUCT SEA reserves the right to do changes or variations that may be necessary to its products with no obligation to notice Fig 28 RISK...

Page 19: ...ust contact SEAfor instructions WARRANTY for the original buyer only Hydraulic and oil bath motors 36 months warranty from the date of invoice on manufacturing assembling and workmanship defects Elect...

Page 20: ...850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 USA Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 web site www sea usa com e mail sales sea usa com International registered tradema...

Reviews: