Note:
To start the Auto-test on safety devices just connect the positive input on 2 24 FL and the
negative input on 0 OPT2, then set
Auto-test
function on 4-menu
24VAux
SA ETY DE ICES CONNECTIONS
On the 24 AU you can select when and how to operate the connected auxiliary accessory
See
4-menu
24VAux
Options available are:
Always - In cycle - Opening - Closing - In pause - Autotest
In cycle and fototest - Positive brake management - Negative brake management
MENU
94-24V AU
SEA
SET
International registered trademark n. 2.777.971
R 1
T 1
CN1
1 2 3 4 5 6 7 8 9
10
11
12
13
C
6
7
11
12
11
12
24 FL COM 0 PH Photocell contact
Default setting: PHOTO
Closing
For photocell options see menu- 7
AUTOTEST Function
: Check that the photocells are working properly
before each movement. If the test fails this will be indicated on the display.
To start the AUTO-TEST:
1)
Connect the T photocell power on 24 FL input
12
and
10
2)
Access the 4-menu
24VAux
and activate
Auto-test
mode
Note
: Auto-test is possible only when the photocell T is powered between
positive input 2 24 FL and negative input 0 OPT2
24V DC 12 P OTOCELL 1 (LOOP 1)
24V DC AU PROGRAMMA LE ON OPT2 10 OUTPUT
Note: The indicated maximum load of 200 mA refers to the maximum load distributed on all 24V outputs
START
START
PARTIAL
OPENING
STOP
CN1
1 2 3 4 5 6 7 8 9
10
11
12
13
ANTENNA
C
6
6
6
3
4
5
START N.O. 3
Function 1 (STANDARD):
partial opening space is adjustble from 20
to 00
Menu-90 Partial Opening
Function 2 (TIMER):
by holding the partial opening button the
gate opens and then stay open. When release the gate repeat
the pause time set and then closes. In case a safety device is
activated the timer will automatically reset after 6 seconds
Function 3 (2 UTTONS):
in 2 buttons logic press the partial
opening button to close the gate
Function 4 (DEADMAN):
To re-close the gate keep
pressed the partial opening button in deadman logic
PARTIAL OPENING N.O. 4
Function 1 (STANDARD):
a
n impulse given to this contact opens and closes the automation according
to the selected logic
Function 2 (TIMER):
holding START the TIMER function is activated, when released, the operator
repeats the pause time set then closes.
To connect the other devices refer to their instructions ie.
loop detectors .
In case of activation of a safety device the timer will automatically reset after 6 sec.
Function 3 (2 UTTONS):
in 2 buttons logic this button performs the opening
Function 4 (DEADMAN):
in deadman logic keep pressed START to open the automation
STOP N.C. 5
When pressing this button the motor immediately stops
in any condition or position. To re-start the movement give a Start command. After the Stop command the
motor always re-starts in closing
START ARTIAL O ENIN START STO CONNECTIONS