Release the operator.
-
Open the leaf completely or up to the desired opening point.
-
Position the stop as in Fig. 24 on the stop of the arm and lock the screws as in Fig. 25.
N.B: The delivered screws are selfthreading and have to be locked at 10 Nm.
FLIPPER
RIGHT MOTOR
LEFT MOTOR
Closing
Opening
Opening
Closing
STOP
STOP
STOP
STOP
Fig. 20
Fig. 21
Fig. 25
10 m
m
m
ax
LEFTHAND MOUNTING
RIGHTHAND MOUNTING
Fig. 22
Fig. 23
10
mm
max
Fig. 24
MECHANICAL POSITIVE STOP ADJUSTMENT IN OPENING
FITTING AND CONNECTION INSTRUCTIONS
ENGLISH
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
24
REV 02 - 03/2009