IMPORTANT: SEA recommend to install at least 2 separate non contact sensor as on the 
post close to the gate as at furthest point of the opened gate where the risk of entrapment 
exists in order to avoid any risk of damage/injury (see pg. 11 Typical Installation). SEA also 
recommend to install infrared Photo beam for a higher performance of use.

9) For a gate operator utilizing a contact sensor (Edge sensor or like) in accordance with section 
31.1.1 of the UL 325 standards:

I. One or more contact sensors shall be located where the risk of entrapment or obstruction 

exists, such as at leading edge, trailing edge, and post mounted both inside and outside of a 
vehicular horizontal slide gate.

II.

One or more contact sensor shall be located at the bottom edge of a vehicular vertical lift 
gate.

III. One or more contact sensor shall be located at the pinch point of a vehicular vertical pivot 

gate.

IV. A hardwired contact sensor shall be located and its wiring arranged so that the 

communication between the sensor and the gate operator is not subject to mechanical 
damage.

V.

A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate 
operator for entrapment protection functions shall be located where the transmission of the 
signals are not obstructed or impeded by building structures, natural landscaping or similar 
obstruction. A wireless contact sensor shall function under the intended end-use conditions.

VI. In case of a swing gate one or more contact sensors shall be located on the inside and 

outside leading edge of the gate. Additionally, if the bottom edge of a swing gate is greater 
than 6 inches (152mm) above the ground at any point in its arc of travel, one or more contact 
sensors shall be located on the bottom edge (see pg..for Typical Installation)

VII. One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm)

SEA warns that the gate operator system with an A.C. power electric motor shall have a 
reversing sensor (encoder) on the drive shaft of the motor as additional safety device. In 
case of swing linear/in-ground hydraulic operator SEA recommend to install the “SAFETY 
GATE” as an additional reversing sensor.

11) The professional installer has to check that the main power supply circuit breakers are 
separate, intended solely for this equipment and rated for 15 AMPS. Visually check that the circuit 
breakers are in the "OFF" position and mark the circuit breakers "USED" prior to installation.

12) During service the main power MUST always being disconnected.

13) If this gate operator system includes a battery backup, the battery backup system needs to be 
disconnected first, prior to disconnecting main power supply during installation, maintenance and 
servicing procedures.

14) After installation The professional installer has to check that the gate operator system is 
working properly, that the open and close force are properly adjusted, that the piston does not 
bottom out in either direction, that breather screws have been removed, that the positive stops used 
are sufficient for stopping the gate properly, and that all pinch points and potential entrapment 
areas are reduced.

ALPHA

SAVE THESE INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

4

International registered trademark n. 2.777.971

REV 03 - 06/2009

Summary of Contents for ALPHA 330 STANDARD

Page 1: ...e www sea usa com e mail sales sea usa com REV 03 06 2009 67410780 L 5 I 2 S 3 T L E U D I T S O N A International registered trademark n 2 777 971 SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Flor...

Page 2: ...8 PRECAUTIONS 8 B INSTALLATION MANUAL 9 DIMENSIONS 9 STANDARD INSTALLATION 10 11 11 DIMENSIONS FOR INSTALLATION 12 15 RISK EXAMINATION 15 TECHNICAL FEATURES GATE ARRANGEMENT INSTALLATION OF THE OPERA...

Page 3: ...gate Make any necessary repairs to the gate before installing this equipment 5 The gate operator controls MUST be placed so that the user has full view of the gate area when the gate is moving and aw...

Page 4: ...and outside leading edge of the gate Additionally if the bottom edge of a swing gate is greater than 6 inches 152mm above the ground at any point in its arc of travel one or more contact sensors shall...

Page 5: ...und or requires a ground and ali of the surge suppressors The ground bus is a common ground point calied a Single Point Ground SPG It is used to bond all the equipment and device grounds in the IGZ to...

Page 6: ...l location or building such as a factory or loading dock area or other locations not intended to service the general public RESTRICTEDACCESS VEHICULAR GATE OPERATOR CLASS IV A vehicular gate operator...

Page 7: ...e leaf and lubricate it with recommended lubricant 6 Check for all corroded parts and replace them 7 Check the tight of the hardware of the gate 8 Check the operating of all accessories Especially the...

Page 8: ...TIONS ALPHA has been created for the automation of gates used by vehicles only Be aware to avoid the crossing of the gate path because it is very dangerous for pedestrians fig 4 Install the warning si...

Page 9: ...A is provided with a mechanical locking system that grants the operator locking in the opened and closed position avoiding any needs for electric locks and or magnetic locks The torque intensity and t...

Page 10: ...photocells 10 Warning notice outside TYPICAL INSTALLATION Fig 8 1 1 3 3 9 9 9 9 1 1 4 4 5 5 8 8 2 2 6 6 7 7 SAFETY LOOP EX T LOOP I O CENTER L OP F Y L SA ET OOP IN OUT 10 10 Notice The operator must...

Page 11: ...Fig 10 Fig 10 Limit Switch stop in opening Limit Switch stop in closing Fig 11 Fig 12 2 INSTALLATION OF THE OPERATORS 2 1 Fix the holed mounting plate to the post using screws as shown in Fig 11 The p...

Page 12: ...4 33 A B A B 90 120 5 51 7 08 7 48 5 90 6 69 7 87 6 69 6 29 6 29 8 66 6 29 See Fig 15 A C Fig 14 in 2 M IN Fig 15 Opening angle During selection prefer the higher dimensions of A and B The above menti...

Page 13: ...into the opposit direction screw it see Fig 17 and 18 Note After installation in opening leave minimum 0 59 inches of working stroke to avoid that the operator goes into mechanical lock if necessary i...

Page 14: ...f it is not possible to attach the front bracket with the bolts weld it to the gate Fig 22 being careful to protect the shaft from welding waste ALPHA 14 International registered trademark n 2 777 971...

Page 15: ...registered trademark n 2 777 971 CONNECTIONS Fig 25 Fig 26 2 9 Release the arm see paragraph 3 2 10 Remove the pull tongue from the shaft cover Fig 25 and mount it on the operator through the two tie...

Page 16: ...has been made NOTICE SEA s r l can not be deemed responsible for any damage or accident caused by product breaking being damages or accidents due to a failure to comply with the instructions herein Th...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...sea usa com e mail sales sea usa com SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 International registered trademark...

Reviews: