background image

GATE WARNINGS 

The first thing to check is that the gate is in good running order as 
follows:

A. 

The gate is rigid and straight and runs smoothly throughout its travel.

B. 

The length of each leaf is not over 6,6 feet (ALPHA 200), 10,8 feet 

(ALPHA 330).

C.

The weight of each leaf is not over 440 Pound (ALPHA 200), 661 

Pound (ALPHA 330).

D.

The hinges are hardly anchored and are able to support the torque of 

the operator; they do not have irregular movements and/or any friction 
during the whole movement of the leaf.

PRECAUTIONS

ALPHA has been created for the automation of gates used by vehicles 
only. Be aware to avoid   the crossing of the gate path because it is very 
dangerous for pedestrians (fig. 4).

Install the warning signs, on each side of the gate and in avisible 
zone

Important:
For a higher security, SEA advices to install infrared photocells.

 

which informs the pedestrians about the danger they run when 

passing or resting in the environment of the gate (fig. 5). 

GATE WARNINGS AND PRECAUTIONS

ALPHA

 

- Install the operator in the correct position

- Do not Install the front bracket in a weak part of the gate

- Not for pedestrian opening

8

Fig. 4

Fig. 3

Fig. 2

Fig. 5

International registered trademark n. 2.777.971

REV 03 - 06/2009

Fig. 1

Summary of Contents for ALPHA 330 STANDARD

Page 1: ...e www sea usa com e mail sales sea usa com REV 03 06 2009 67410780 L 5 I 2 S 3 T L E U D I T S O N A International registered trademark n 2 777 971 SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Flor...

Page 2: ...8 PRECAUTIONS 8 B INSTALLATION MANUAL 9 DIMENSIONS 9 STANDARD INSTALLATION 10 11 11 DIMENSIONS FOR INSTALLATION 12 15 RISK EXAMINATION 15 TECHNICAL FEATURES GATE ARRANGEMENT INSTALLATION OF THE OPERA...

Page 3: ...gate Make any necessary repairs to the gate before installing this equipment 5 The gate operator controls MUST be placed so that the user has full view of the gate area when the gate is moving and aw...

Page 4: ...and outside leading edge of the gate Additionally if the bottom edge of a swing gate is greater than 6 inches 152mm above the ground at any point in its arc of travel one or more contact sensors shall...

Page 5: ...und or requires a ground and ali of the surge suppressors The ground bus is a common ground point calied a Single Point Ground SPG It is used to bond all the equipment and device grounds in the IGZ to...

Page 6: ...l location or building such as a factory or loading dock area or other locations not intended to service the general public RESTRICTEDACCESS VEHICULAR GATE OPERATOR CLASS IV A vehicular gate operator...

Page 7: ...e leaf and lubricate it with recommended lubricant 6 Check for all corroded parts and replace them 7 Check the tight of the hardware of the gate 8 Check the operating of all accessories Especially the...

Page 8: ...TIONS ALPHA has been created for the automation of gates used by vehicles only Be aware to avoid the crossing of the gate path because it is very dangerous for pedestrians fig 4 Install the warning si...

Page 9: ...A is provided with a mechanical locking system that grants the operator locking in the opened and closed position avoiding any needs for electric locks and or magnetic locks The torque intensity and t...

Page 10: ...photocells 10 Warning notice outside TYPICAL INSTALLATION Fig 8 1 1 3 3 9 9 9 9 1 1 4 4 5 5 8 8 2 2 6 6 7 7 SAFETY LOOP EX T LOOP I O CENTER L OP F Y L SA ET OOP IN OUT 10 10 Notice The operator must...

Page 11: ...Fig 10 Fig 10 Limit Switch stop in opening Limit Switch stop in closing Fig 11 Fig 12 2 INSTALLATION OF THE OPERATORS 2 1 Fix the holed mounting plate to the post using screws as shown in Fig 11 The p...

Page 12: ...4 33 A B A B 90 120 5 51 7 08 7 48 5 90 6 69 7 87 6 69 6 29 6 29 8 66 6 29 See Fig 15 A C Fig 14 in 2 M IN Fig 15 Opening angle During selection prefer the higher dimensions of A and B The above menti...

Page 13: ...into the opposit direction screw it see Fig 17 and 18 Note After installation in opening leave minimum 0 59 inches of working stroke to avoid that the operator goes into mechanical lock if necessary i...

Page 14: ...f it is not possible to attach the front bracket with the bolts weld it to the gate Fig 22 being careful to protect the shaft from welding waste ALPHA 14 International registered trademark n 2 777 971...

Page 15: ...registered trademark n 2 777 971 CONNECTIONS Fig 25 Fig 26 2 9 Release the arm see paragraph 3 2 10 Remove the pull tongue from the shaft cover Fig 25 and mount it on the operator through the two tie...

Page 16: ...has been made NOTICE SEA s r l can not be deemed responsible for any damage or accident caused by product breaking being damages or accidents due to a failure to comply with the instructions herein Th...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...sea usa com e mail sales sea usa com SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 International registered trademark...

Reviews: