15.
Calibrating
the
Remote
Tilt
Setting:
This
procedure
is
required
to
calibrate
the
level
cage
so
that
all
the
sensors
will
be
accurately
aligned
to
their
axis.
The
fluid
filled
tilt
sensor
provides
a
two
dimensional
horizon
reference.
The
system
is
not
able
to
automatically
calculate
the
exact
center
value,
therefore
it
is
necessary
to
perform
this
procedure
to
manually
enter
any
offset
required
to
make
sure
the
PCU
receives
a
true
horizon
reference.
1.
Turn
dishscan
off:
Enter
into
the
Setup
Menu
by
pressing
and
holding
the
arrows
together
until
the
EL
Trim
or
Auto
Trim
parameter
is
displayed.
Use
the
arrow
key
to
scroll
through
the
menu
until
the
dishscan
window
is
displayed.
Press
the
arrow
to
activate
the
window
and
then
press
the
arrow,
followed
by
the
button
to
turn
dishscan
from
on
to
off.
*Note:
When
you
press
the
arrow
to
turn
dishscan
off
you
won’t
see
the
display
change
until
you
press
the
button.
(
Steps
2
‐
7
requires
assistance
to
observe
and
operate
antenna
simultaneously
)
2.
Enter
into
the
Setup
Menu
by
pressing
and
holding
the
arrows
together
until
the
EL
Trim
or
Auto
Trim
parameter
is
displayed.
3.
Push
the
arrow
key
until
the
Remote
Tilt
window
is
displayed.
4.
Push
the
arrow
key
to
activate
the
Remote
Tilt
setting.
5.
Use
the
arrow
keys
to
position
the
bubble
as
close
to
the
center
as
possible.
Each
press
of
an
arrow
key
on
the
directional
pad
will
move
the
Remote
Tilt
½
a
degree.
It
is
advised
that
you
only
press
the
button
once
and
wait
for
the
axis
to
move
before
pressing
it
again.
When
standing
behind
the
antenna
looking
at
the
bubble,
if
the
bubble
is
over
to
the
right,
you
need
to
press
the
(right)
arrow
to
bring
the
bubble
into
the
center.
If
the
bubble
is
down
towards
you,
you
need
to
press
the
(down)
arrow
to
bring
it
towards
the
center.
If
the
bubble
is
to
the
left,
you
need
to
press
the
(left)
arrow
and
if
the
bubble
is
up
towards
the
top,
you
need
press
the
(up)
arrow
to
move
it
towards