Procedure, Field Replacement, Level Cage Kit, Base Exit
Page
9
of
9
Document No
135266 Rev B
Copyright © Sea Tel, Inc 2011 - The information contained in this document is proprietary to Sea
Tel, Inc.. This document may not be reproduced or distributed in any form without prior written
consent of Sea Tel, Inc.
When
correct
the
bubble
should
be
as
close
to
the
center
of
the
fluid
as
possible
6.
When
the
bubble
is
as
central
as
possible
press
the
button
to
deactivate
the
Remote
Tilt
setting.
7.
Turn
dishscan
on:
Enter
into
the
Setup
Menu
by
pressing
and
holding
the
arrows
until
either
the
EL
Trim
or
Auto
Trim
parameter
is
displayed.
Use
the
arrow
key
to
scroll
through
the
menu
until
the
dishscan
window
is
displayed.
Press
the
arrow
key
to
activate
the
window
and
then
press
the
arrow
key,
followed
by
the
button
to
turn
dishscan
from
off
to
on.
*Note:
When
you
press
the
arrow
to
turn
dishscan
on
you
won’t
see
the
display
change
until
you
press
the
button.
8.
Save
the
Remote
Tilt
setting
in
the
PCU:
Press
the
arrow
key
until
the
Remote
Parameters
window
is
displayed.
Press
the
arrow
key
to
activate
the
window
followed
by
the
button
(you’ll
see
a
confirmation
on
the
display
saying
“Saved”).
9.
As
good
practice
make
a
note
of
your
N4
and
N5
parameters
once
you
have
correctly
set
the
remote
tilt.
The
N4
and
N5
parameters
are
a
numeric
read
of
the
remote
tilt.
To
do
this
go
to
the
remote
command
window
and
key
in
N4999
to
read
the
CL
setting,
followed
by
N5999
to
read
the
EL
setting.