390 Sundancer
®
(
425 Sundancer
®
)
7.2
S
ECTION
7 • A
CCESSORIES
AND
O
PTIONS
located on the port hanging closet wall. The
removable air filter can be accessed by lifting the
hatch under the bottom of the bunk mattress.
The salon unit is a 12,000 BTU unit which also
services the Aft Stateroom & Head. The unit is
located on the port side, aft of the sofa under the
MDP cabinet. The controls for the unit are located
on the aft wall of the port light window ledge above
the port sofa. The removable air filter is located on
the face of the unit.
The system is cooled to maintain optimal operating
temperature by the raw water pump located in the
bilge. The pump draws water through a seacock and
filters it through a sea water strainer. The water
passes through each compressor cooling the
condensing coils, then flows overboard through the
thru-hull vents. (The sea water strainer should be
inspected frequently and cleaned out when plugged.
To clean strainer, refer to Section 4-
Bilge &
Underwater Gear, pg. 4.11, Seacocks & Strainers).
The condensation drains for the compressor units
connect to the cabin sump.
A. T
O
S
TART
S
YSTEM
:
1. Make sure the seacock for the cooling water
pump is open.
2. Turn ON the A/C WATER PUMP/RELAY circuit
breaker on the main AC distribution panel. Turn
ON each A/C UNIT circuit breaker located on
the same panel.
3. Refer to air conditioner owner’s manual in the
owner’s packet for instructions on operation of
the control panels.
REFER TO OWNER’S MANUAL PACKET FOR
INSTRUCTIONS AND WARRANTY INFORMATION.
4. W
ATER
S
YSTEM
The fresh water system consists of a 100 gallon
(378.5 liter) water tank, a 12 volt water pump,
water heater and accumulator tank.
The fresh water system is activated by the fresh
water pump breaker on the salon 12VDC distribution
panel. The breaker must be ON to operate the head,
shower, ice maker, fresh water washdowns and
faucets. The hot and cold water lines throughout
the boat are color coded: RED (hot) and BLUE
(cold).
A
IR
C
ONDITIONING
/H
EATING
L
OCATIONS
(F
IG
. 7.2.1)
SALON, & AFT
STATEROOM
AIR HANDLER
(12000 BTU)
MASTER
STATEROOM
AIR HANDLER
(7000 BTU)
Summary of Contents for 390 Sundancer
Page 2: ...390 Sundancer 425 Sundancer ii THIS PAGE LEFT INTENTIONALLY BLANK...
Page 12: ...390 Sundancer 425 Sundancer xii THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Page 30: ...390 Sundancer 425 Sundancer 1 18 SECTION 1 SAFETY THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Page 34: ...390 Sundancer 425 Sundancer 1 22 SECTION 1 SAFETY THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Page 102: ...390 Sundancer 425 Sundancer 5 6 SECTION 5 FUEL SYSTEM THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Page 184: ...390 Sundancer 425 Sundancer Index 4 INDEX THIS PAGE LEFT INTENTIONALLY BLANK...