background image

 

- 11 - 

 

 
 

INTERNATIONAL REFRIGERATION PRODUCTS CO., INC. 

LIMITED WARRANTY POLICY 

 
 

 

 

In te rn ati o na l Re frig e rati on Pr od uc ts Co., In c. (H e rei n after re fer red to a s 

“IR P”) wa rra nts the fo ll o wi ng :
Onl y cata lo g ed p rod uc ts so l d to d is tr ib uto rs ar e war ran te d to th e ori gi n al 
p urc ha se r, to con for m with sp eci fi cati o ns furn i she d or ap pr ove d by IRP, and 
to be fre e fro m defe cts in mate ri al a nd w or kma nsh ip , fo r a peri o d of one (1 ) 
ye ar fro m th e da te of pur cha se , un l ess sp eci fi ed i n wri tin g for a di ffere nt 
p eri o d.  Pri o r to re turn i ng th is pro d uct to IR P, th e pu rch a ser sh al l gi ve IRP 
n oti ce in w ri tin g stati ng h ow th is pr od uct fai ls to ful fil l thi s wa rra nty.  No 
p rod u ct sh al l be a cce pte d for re pa ir or re pl ac eme nt wi tho ut a req ui re d 
w ritte n no tic e an d wi th o ut pri or wr itte n au tho ri zati on a nd sh i pp in g ad dr ess 
h avi n g be en re ce ive d by the p ur cha se r fro m IR P.  Onl y IRP' s fa ctor y is 
a uth ori ze d to pe rfor m se rvi ce s und er thi s wa rra nty.  Tr an sp orta tio n ch arg es 
a re to be pr ep ai d by the p ur cha se r.
Thi s wa rra nty do es no t exte nd to an y pro du ct th at ha s bee n sub j ecte d to 
mi su se, ab us e, neg l ect, acc id en ts, alte rn ati on s, imp rop e r insta l la tio n or us e 
i n vio l ati on o f the p ri nte d in stru ctio ns fur ni sh ed b y IR P. Th is wa rra nty ne i the r 
a pp li e s to ba tter ie s not de teri o rati o n of, nor da ma ge to the p rod u ct ca us ed by 
th e use o f fau lty ba tter ie s.  Fin a l de te rmi n ati on a s to wh e the r any pr od uct is 
a ctua l ly de fecti ve re sts sol e ly wi th IR P.
Thi s wa rra nty is ex pre ssl y in l ie u of al l oth er ag re eme nts an d wa rra n ti e s, 
e xpr ess ed , impl i ed , or sta tuto ry an d IR P has no o the r obl i ga tio ns o r lia bi l iti es 
i n con ne cti on w ith th is pro d uct.  In no e ve nt sha ll IR P's ob l ig ati on o r li ab il i ty 
h ere u nd er ex cee d the p urc ha se pr ice o f th is pro d uct.

IRP SHA LL NOT IN A N Y EV ENT BE LIA BLE FOR A N Y IN CID ENTAL OR 

C ON SEQU ENTIA L DA MAGE S.  

Thi s wa rra nty gi ve s yo u sp eci fi c leg al r ig hts, an d you a ls o ha ve oth er ri gh ts 
w hi ch va ry fr om state to sta te.  So me state s do no t all ow th e exc lu si on o r 
l imi ta ti o n of inc id en tal o r con se qu en tia l da ma ge s, or imp li ed w ar ran tie s, so 
th e ab ove l im ita tio ns or ex cl usi on ma y no t ap p ly to you .

INTERNAT IONAL REFRIGERATION PRODUCTS CO ., INC.

LI MIT ED WARRANTY POL ICY

INTERNAT IONAL REFRIGERATION PRODUCTS CO ., INC.

Langh orne, PA 19047

www.i rpro duct s. biz

 

 

 

 

INTERNATIONAL REFRIGERATION PRODUCTS CO., INC. 

Langhorne, PA 19047 

www.irproducts.biz 

                                                                                                                                                         

 

International Refrigeration Products Co., Inc. (Hereinafter referred to as IRP”) 
warrants the following: 
Only cataloged products sold to distributors are warranted to the original   
purchaser, to conform with specifications furnished or approved by IRP, and   
to be free from defects in material and workmanship, for a period of one (1)   
year from the date of purchase, unless specified in writing for a different   
period.    Prior to returning this product to IRP, the purchaser shall give IRP   
notice in writing stating how this product fails to fulfill this warranty.    No   
product shall be accepted for repair or replacement without a required   
written notice and without prior written authorization and shipping address   
having been received by the purchaser from IRP.    Only IRP's factory is   
authorized to perform services under this warranty.    Transportation charges 
are to be prepaid by the purchaser. 
This warranty does not extend to any product that has been subjected to   
misuse, abuse, neglect, accidents, alternations, improper installation or use   
in violation of the printed instructions furnished by IRP. This warranty neither   
applies to batteries not deterioration of, nor damage to the product caused by   
the use of faulty batteries.    Final determination as to whether any product is   
actually defective rests solely with IRP. 
This warranty is expressly in lieu of all other agreements and warranties,   
expressed, implied, or statutory and IRP has no other obligations or liabilities   
in connection with this product.    In no event shall IRP's obligation or liability   
hereunder exceed the purchase price of this product. 

IRP SHALL NOT IN ANY EVENT BE LIABLE FOR ANY INCIDENTAL OR   
CONSEQUENTIAL DAMAGES.

     

This warranty gives you specific legal rights, and you also have other rights   
which vary from state to state.    Some states do not allow the exclusion or   
limitation of incidental or consequential damages, or implied warranties, so   
the above limitations or exclusion may not apply to you. 

Summary of Contents for SN12I

Page 1: ...Safety Information 1 Remove the Old Thermostat 3 Install the New Thermostat 4 Configuration 5 Configuration Menu Chart 6 Parameters 6 System Check 8 Basic Thermostat Operation 9 Troubleshooting 10 Wa...

Page 2: ...n clock function IMPORTANT SAFETY INFORMATION Use a professional contractor to install this thermostat Read all of the information in this manual before installing this thermostat WARNING Electrical S...

Page 3: ...vice Reminder Time Day Setting Low Battery Icon Configuration Compressor Lockout Delay SET TO AM MON SERVICE FILTER CONFIG COMP DELAY ON AUTO AUX EMH Figure 1 THERMOSTAT BUTTONS AND SWITCHES Figure 2...

Page 4: ...OFF position 3 Remove the cover of the old thermostat This should expose the wires 4 Label the wires from the existing thermostat using the enclosed wire markers and record in the chart below before r...

Page 5: ...ing screws and anchors provided mount the thermostat base loosely to the wall or junction box See Figure 3B 6 Place a level against the bottom of the base and adjust until level then tighten the screw...

Page 6: ...the battery compartment Install two fresh AA alkaline batteries in the battery compartment CAUTION Installing batteries backwards can damage the thermostat Be sure to match positive and negative ends...

Page 7: ...compressor from short cycling you can select the minimum length of time the compressor will turn off between cycles from 0 to 5 minutes in 1 minute increments When a compressor lockout delay occurs CO...

Page 8: ...the number of days is also displayed in the upper left corner of the LCD A selection of 00 will deactivate this feature When SERVICE FILTER is displayed in EMH HEAT or COOL mode it can be cleared by...

Page 9: ...ow setpoint and turn off at setpoint The auxiliary heat will activate when the room temperature is below the setpoint by the auxiliary heat offset value AU plus heating cycle rate value HC as establis...

Page 10: ...e SL ow cooling cycle rate is selected the thermostat will call for cooling when the room temperature is 1 5 F 1 C above setpoint and turn off at setpoint 3 When the thermostat calls for cooling will...

Page 11: ...e If no buttons are pressed within 15 seconds the thermostat will exit to normal operation 4 In filter review mode press and hold the and buttons at the same time to reset the amount of time until the...

Page 12: ...itations or ex clusion may not a pply to you INTERNATIONAL REFRIGERATION PRODUCTS CO INC LIMITED WARRANTY POLICY INTERNATIONAL REFRIGERATION PRODUCTS CO INC Langhorne PA 19047 www irproducts biz INTE...