Alarm Module Testing:
Install at least one sensor into any of the (9) nine sensor ports
making sure the sensor(s) are attached properly, and arm the
unit using the keypad instructions.
When the unit is Armed:
Each port that has a sensor
plugged into it will flash for about (2) seconds. At the end of
five seconds, the green program light at the top of the Alarm
Module will flash once every fifteen (15) seconds.
The Red Light(s) Flashing for (2) Seconds Indicates: That
the unit has located that sensor and it is “Working Correctly.”
The Green Light that Flashes Every (15) Seconds
Indicates: That the unit is constantly checking the condition of
the batteries, and they are in GOOD Condition.
Low Battery Indication: Battery Mode Only: The GREEN
indicator light will continually flash and the horn will “Beep”,
(approx. every 10 seconds). With AC/DC Power Supply: The
GREEN indicator light will flash and the horn will “Beep” con-
tinually (approx. 4 times per second). The alarm will not allow
you to silence it until the batteries have been removed, and
replaced with fresh 9 volt alkaline batteries.
Operating Instructions:
1.
Dis-Arm the K-9 WatchDog Alarm Module by entering the
Current Access Code on the keypad.
2.
Connect a sensor to the merchandise that is to be pro-
tected, then plug it into one of the (9) nine sensor ports.
Continue plugging sensors into the Alarm Module after they
have been attached to merchandise. You may use all nine sen-
sor ports.
3.
Activate the alarm by entering the Access Code. The K-9
WatchDog Alarm Module will now independently scan the sen-
sor ports for tampering. The unit continually checks the battery
condition with a GREEN flashing light to show it is operating.
Tampering: can be defined here as the removal of Sensors
from the Alarm Module, from Merchandise, Inserting Metal
Objects into Open Sensor Ports, or cutting a sensor wire.
4.
To add or remove Sensors: De-Activate the alarm by
entering the access code on the keypad. While the unit is in the
Dis-Armed Mode, it will “Beep” once every 15 seconds after the
first 1-1/2 minutes to warn employees to turn the unit back on.
5.
To Re-Set the K-9 WatchDog Alarm Module after an
Alarm: Enter the Access Code on the keypad.
Note: During “Alarm Mode” and after the access code has
been entered on the keypad, the RED indicator lights will
continue to flash, indicating which sensor caused the
alarm. Correct the problem sensor that caused the alarm and
re-enter the access code.
The K-9 WatchDog Alarm will
always search through its ports and check battery condition
when activated by the correct access code.
The SK-K9 WatchDog Alarm Module requires NO SHUNT PLUGS,
and is a perfect choice
for End Caps without AC power. Alkaline batteries may provide enough power for the unit to protect display
merchandise for a year. When the AC/DC Power Supply is plugged into the unit, it will light the Port Lights and
Sensors that are plugged into them. The unit will continue to provide security to the sensors plugged into it with-
out the use of the AC/DC Power Supply, but will not light up until a sensor has caused an alarm.
The K-9 WatchDog Alarm utilizes our complete array of electronic sensors and recoilers.
Ask your Customer Service Representative for information on sensors to meet your needs.
Keypad Instructions:
Features:
The Keypad System is intended to
replace a mechanical key lock system.
Entering your access code will
either arm or disarm the alarm module.
The Yellow LED Light above the keypad indicates when
the device is in the “Program Mode” and able to accept
new access codes from the user.
During an alarm, when the horn is )))sounding(((, you can
enter your security access code on the keypad to place
the system in the Dis-Armed Mode.
The Keypad System features a device called Auto-Arm. it
is intended to automatically arm the system after a prede-
termined amount of time. The system will automatically go
into the Armed State after a delay of (4.4) minutes.
Operation of the Keypad Lock System:
When power is first applied to the device, it will use the fac-
tory default code of : 1, 2, 3, 4. The user should change this
code as soon as possible.
The system will accept the
default code until a new one has been entered.
Always enter the [
*
] key before entering the access code.
Changing the Default Access Code:
Follow the steps below to change the access code as
desired. The codes cannot contain the [
*
] star or the [#]
pound symbol keys! The system must be in the “Dis-Armed”
Mode before changing the code.
1.
PRESS [#]
2.
ENTER the current (4) digit Security Code:
[________] + [________] + [________] + [________]
3.
PRESS [
*
]
(After Step 3, the Yellow LED Light will be ON).
4.
ENTER the new (4) digit Security Code:
[________] + [________] + [________] + [________]
5.
PRESS [
*
] (One More Time) then
PRESS [#] (To Store the New Code)
Note: The steps to change the Access Code must be done
within (8) eight seconds, or the keypad will be reset to the
last stored security code, and you will be required to repeat
the steps.
On the Web: www.se-kure.com