LUBExpert User Manual
34/52
•
In case you decide to ignore alarm recommendations, you must then assign a message in
order to see the menu that lets you continue to
ADD GREASE
. In that case, press M, select a
message and press ENTER. Your message is now added to the asset and marked as a
manually added message. The following screen appears:
•
You are once more reminded that lubrication is not needed, and you can still select to exit.
•
If you want to add grease, you can choose
GUIDED MODE
or
FREE MODE
by pressing F2 or
F3
•
Follow either process as explained in previous case.
•
Difference on the screen will be alarm status:
•
Alarm ICON means that an alarm is assigned. When the Alarm ICON has a cross through it,
this indicates that no alarm was triggered. An uncrossed Alarm ICON means that an alarm
was triggered
③
ALARM ASSIGNED AND TRIGGERED
In case there is an alarm assigned, and triggered, you
are informed that Lubrication is needed. You have an
option to continue in GUIDED MODE or FREE MODE.
In case you want to ignore this recommendation and
abort lubrication, you need to press M, assign the
message and then exit.
•
LUBRICATION NEEDED
message will be assigned automatically and will be marked as an
automatic status/action message
•
In case you decide to follow the alarm recommendations you can choose
GUIDED MODE
or
FREE MODE
and follow the process as described in case 1 above.