9. Troubleshooting
Problems
Probable causes
Possible solutions
Engine does not
start
Load connected to the generating set during start-up.
Disconnect the load.
Air filter (fig. A – No.14) blocked.
Clean the air filter
(see § Cleaning the air filter)
.
Fuel level too low
Fill up with fuel
(see § Filling up with fuel).
Fuel filter (fig. A – No.13) blocked.
Replace the fuel filter
(see § Replacement of the fuel
filter)
.
Oil level too low.
Check the oil level and fill up if necessary
(see. § Checking of oil level)
.
Starter battery (fig. A – No.15) defective.
Recharge or replace the starter battery.
Fuel supply blocked or leaking.
Have it checked, repaired or replaced.*
Engine stopped
Fuel level too low
Fill up with fuel
(see § Filling up with fuel).
Oil level too low.
Check the oil level and fill up if necessary
(
see. § Checking of oil level
).
No electric
current
Circuit breakers (fig. A – No. 8) not activated.
Activate the circuit breakers.
Defective devices supply lead
Change the lead
Defective electrical sockets (fig. A - No 9).
Have it checked, repaired or replaced.*
Defective alternator.
Have it checked, repaired or replaced.*
Triggering the
circuit breakers
Device connected or faulty lead.
Disconnect the device and the lead.
Overload
(see § Capacity of the generating set).
Remove the overload.
* Operation(s) to be entrusted to one of our agents.
10. Specifications
Model
DIESEL 6500 TE XL C
Maximum output / Rated output
5200 W / 4160 W
Acoustic pressure at 1 m
95 dB(A)
Engine type
Kohler KD440
Recommended fuel and fuel tank capacity
Diesel oil
16 L
Recommended oil and oil sump capacity
SAE 5W40
1.5 L
Oil failure cut-out
●
Circuit breaker
●
Direct Current
X
Alternating Current
230V – 10A
400V – 6A
Socket types
2P+T 230V 10/16A
3P+T+N 400V 16A
Spark plug type
X
Battery
●
Dimensions L x l x h
81 x 55.5 x 59 cm
Weight (without fuel)
103 kg
●
: Standard
○
: Option
X : Not applicable
Summary of Contents for 6500 TE
Page 2: ...A O I 4 3 7 16 14 8 9 6 10 STOP 13 12 11 2 5 15 1...
Page 3: ...B C 1 3 2 4 5 6 1 2 3...
Page 4: ...D 1 3 4 5 6 2...
Page 75: ...1 2 3 4 5 6 7 8 9 10 11 12 13 1 1 1 1 2 1 2 3 1 2 3 A B C D E F G H I J K 1 3 1 3 1...
Page 76: ...1 3 2 1 3 3 1 a I PE II 60245 4 b 30 A 1 2 1 a 1 1...
Page 80: ...4 3 n A 9 o 1 2 p A 5 A A 10 A 5 5 1 5 2 6 6 1 6 2 1 1 10 1 2 50 1 6 250 1 500...
Page 82: ...7 5 n D 1 2 o D 3 4 5 1 2 1 2 p q D 6 r 7 6 7 7 n o p 8 n o p q r s...
Page 115: ...1 2 3 4 5 6 7 8 9 10 11 12 13 1 1 1 1 2 1 2 3 1 2 3 A B C D E F G H I J K 1 3 1 3 1...
Page 116: ...1 3 2 1 3 3 1 I PE II IEC 60245 4 30mA 1 2 1 1 1...
Page 122: ...7 4 n 1 C 1 2 o C 2 p C 3 q A 13 r s t u 7 5 n D 1 2 o D 3 4 5 1 2 1 2 p q D 6 r 7 6 7 7 n o p...