2.2.2 Mutual interference prevention
WARNING
Install the emitter and receiver in parallel,so that their vertical direction should match.
If the vibration of the work environment exceeds the specified value, other measures should be
taken to reduce the vibration.
Installation should strictly abide by the provisions of the safe distance. Refer to 3.1.2 about
calculation of actual safety distance.
The installation of KS06 should make sure that the hazardous part of a machine can not be reached
by passing through the upper, lower and back side of the detection zone. And the installation
position can not be changed after installed.
Install a protective structure so that the hazardous part of a machine can only be reached by passing
through the sensor's detection zone. Install the sensors so that part of the person is always present
in the detection zone when working in a machine's hazardous zones. Failure to do so may result in
serious injury.
Make sure that the KS06 is securely mounted and its cables and connectors are properly connected.
1) ZC mounting (ZC)
Sheet2.1 Formula of Dimension A, B and H
Fig 2.8 ZC mounting (ZC)
①
Emitter/Receiver
②③
ZC-mounting bracket
④
KS06 lower vibration-reducer
⑤
KS06 upper vibration-reducer
⑥⑦
M6×16 inner hexagon screw, Φ6 plain /elastic washer
Fig 2.8.A
Fig 2.8.B
Fig 2.8.C