MOUNTING INSTRUCTIONS KP40U PAD 3X4
The 3x4 keypad is designed to mount to a single gang switchbox or on a wall, pedestal or any flat
surface of at least 3 ½ by 5 ¼”. The composition of the mounting surface will determine the fastening
method required. If mounting to a surface other than a switchbox:
1. Select a flat surface (3 ½” by 5 ¼”) near the door where you wish to install the keypad.
2. Drill the large hole for the Keypad connector using a
⅞
” (25mm) drill bit.
3. Place the connector on the back of the keypad in the large hole. Mark the keypad mounting holes.
4. Drill clearance holes in accordance with fastening method used. (If mounting to wood, drill small
pilot holes and use #6 flat head wood screws provided. If mounting to metal, drill two
5
/
32
" clearance
holes for #6 flat head machine screws provided.)
5. Do
NOT
mount the keypad at this time.
6. Proceed to Install the Wiring Cable.
MOUNTING INSTRUCTIONS KP-30U AND KP-30Y 2X6:
The KP-30 is designed for mullion mount applications. It can also be mounted on a wall, pedestal or
any flat surface of at least 1 ¾” by 7”. The composition of the mounting surface will determine the
fastening method required:
1. Select a flat surface (1 ¾” by 7") near the door where you wish to install the keypad.
2. Using a Thinline template, mark location of holes.
3. Drill the large hole using a
⅞
” or 1” (25mm) drill bit.
4. Place the connector on the back of the keypad in the large hole to verify that the mounting holes are
aligned. Make adjustments if necessary.
5. Drill mounting holes in accordance with fastening method used. (If mounting to plaster, use the #8
wood screws and plastic anchors included with the KP-30)
6. Do
NOT
mount the keypad at this time.
7. Proceed to Install the Wiring Cable.
P:\INSTALLATION INST\ACCESS CONTROL\INST-935.vsd 0505 Page 6