![Sculpt SEGUIN Aurore Installation & User Manual Download Page 9](http://html.mh-extra.com/html/sculpt/seguin-aurore/seguin-aurore_installation-and-user-manual_1220102009.webp)
9
1. SpecificationS
this appliance and flue were tested with the following minimum clearances.
The Seguin Topaze free standing appliance and triple skin flue kit with Solid 8” casing were tested in
two positions in a manner conforming to australian & new Zealand Standards 2918:2018, appendix B.
a minimum
1120mm
deep X
940mm
wide and
18mm
thick non-combustible hearth should be installed,
refer to aS/nZS 2918:2018 3.3 floor protector. the floor protector/hearth should extend
500mm
in front
of the appliance fuel loading door and be placed centrally in the
940mm
width.
Clearances & Hearth- Seguin Topaze
Position b Corner Position
diagram not to scale
Co
Mbustible W
alls
Co
Mbustible W
alls
hearth
1120
MM
940MM
450MM
sWing Door
iMPortant
Please note this appliance has been tested with the installation of a heat shield. these clearances outlined are
for an appliance with a heat shield installed. if the heatshield is not installed, the clearances will increase to
1.2m from combustiable material/walls as per as/nZs 2918:2018 3.2 Clearances & heat shielding.
aPPlianCe
500MM
450MM
Co
M
bustible W
alls
CoMbustible Walls
700MM
225MM
sWing Door
aPPlianCe
500
MM
hearth
1120
MM
940MM
Position a Parallel Position
diagram not to scale