5.
inBUilt into iSlanD Wall
non comBUStiBle SUrroUnDinG
step 1: base
lay a masonry base, minimum 75mm thick (ie. Solid bricks).
the base should be laid on a adequate ground capable of
supporting it’s weight.
step 2: sheet metal layer
(optional step)
place a piece of sheet metal on top of the masonry base, this
will level the base and enable you to safely manoeuvre the
firebox.
allow a minimum of 100mm on all sides if possible.
step 3: side frames
place a steel frame (minimum 51mm thick) on either side of
the enclosure. remember to leave a 25mm air gap on the sides
of the appliance.
**important**
it is strongly recommended that the steel frame allows for a
distance of 300mm to the ceiling, this allows the cavity lid to
be placed directly above and stop heat from traveling above the
lid via the frame.