background image

TB-9023

 Page 5 of 16

© 2017 DESCO INDUSTRIES, INC.

Employee Owned

ESD Event Detection Sensor

The SCS EM Eye Meter will help you detect most ESD 

events. This will help you make sound decisions in 

tackling what may have been a daunting task.  The EM 

Eye Meter detects the magnitude of events and using 

the filters built into the unit.  It can provide approximate 

values for some ESD Events for models (CDM, MM, 

HBM) using proprietary algorithms. Switching between 

any of the modes will give you immediate data analysis. 

Solving ESD problems requires data; a before-and-after 

analysis of data may now be measured and used to 

tailor ESD control programs.

CDM Mode

MM Mode

In IC testing, ICs that are 

sliding through tubes may 

be charged up. Once the 

lead touches the metal 

tracks, a CDM event can 

occur.

A moving, ungrounded 

cart may accumulate 

charges in its path. As 

it approaches a metallic 

worktable and bumps 

into it, a discharge may 

occur and may adversely 

affect nearby products or 

instruments

In feeder bowls where the 

ICs are arranged for sort-

ing or orientation, voltages 

may be induced by the 

vibrating bowl.

In using a bad soldering 

iron, induced voltages 

may cause discharges to 

the components mounted 

into the PCB. Use ground-

ed tools and confirm that 

no ESD events will be 

detected by using the MM 

mode.

HBM Mode

Raw Input Mode

In IC testing, operators 

that are handling an IC 

(i.e. fixing bent leads) may 

be discharging through 

the IC.

For engineers who want 

to simply analyze raw 

ESD signals for further 

analysis, the Raw Input 

mode provides actual 

voltages received by an 

antenna.

During picking up of an IC 

by a person not properly 

wearing a wrist strap, use 

the EM Eye Meter to 

alarm the operator of such 

events.

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for CTC021

Page 1: ...e magnitude of most ESD events when in one of its filter modes electromagnetic fields EMF power density effective isotropic ally radiated power and radio frequency RF Made in the United States of Amer...

Page 2: ...microSD card while the power is on Turn off the meter before removing the microSD card Do not remove the sensor heads while the power is on Turn off the meter before removing and replacing the heads...

Page 3: ...e seconds do not use any tools to perform this action If a new sensor was installed a sequence of initialization will take place for the first time for approximately ten seconds After that the switch...

Page 4: ...n with no storage card in place PREPARING CARD FOR RECORDING DO NOT REMOVE PLEASE WAIT A new card is inserted or when a card is empty WARNING This card contains the data Remove the card or click here...

Page 5: ...t can occur A moving ungrounded cart may accumulate charges in its path As it approaches a metallic worktable and bumps into it a discharge may occur and may adversely affect nearby products or instru...

Page 6: ...damage and other problems For those who install and maintain antennae of radio transmitters and mobile phones the EM Eye Meter can provide readings of the field strength including peak and average va...

Page 7: ...C Employee Owned RF Signal Sensor Display and Controls EM Field Sensor Display and Controls Figure 11 Electromagnetic Field Sensor displays and controls Figure 12 RF Signal Sensor displays and control...

Page 8: ...R C button for approximately one second Figure 14 Using the Hold button Figure 15 Setting the time Battery The BATTERY symbol displays the approximate level of battery life remaining for use Full char...

Page 9: ...appears Press the up down arrows to scroll through functions Press the left or right arrows to set values and options Press the center button to return to the main screen Serial Number The serial numb...

Page 10: ...ure 26 Viewing stored data Figure 22 Navigating through different ESD Filter Models ESD Threshold The THRESHOLD in a form of an ARC LED bar displays the detection level of the ESD events detected When...

Page 11: ...ay For other memory card types please contact SCS Customer Service for verification Electromagnetic Field Sensor Power Density Meter and Effective Isotropically Radiated Power EIRP Meter Display and C...

Page 12: ...evel If any of the reference modes are enabled you should see the REF label shown on the main screen The bottom line of the display will now show the reference value of the peak signal Note The top li...

Page 13: ...od the hardware setup is shown At this point brightness off time and attenuation can be adjusted Attenuation ATT If the input to the antenna is big enough set the attenuation from 0 to 20dB When the a...

Page 14: ...llow you to download the data from the EM Eye Meter and save it to your PC 2 Install the EM Eye File Converter software 3 Remove the microSD card from the EM Eye Meter and insert it into your PC using...

Page 15: ...5 mV 15mV 1500mV Detection Resolution 1mV Threshold Display Resolution 1 10 Volts 10 990 Volts Raw input 1mV 1 15mV and 15mV 15 1500mV Distance Detection Range 1 3 cm 0 5 in 38 1 cm 15 0 in ESD Counte...

Page 16: ...with federal state and local requirements Regulatory Information FCC This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rule...

Reviews: