29
EN
Conduct the following operations at least every 6 months. If in high intensity of use,
shorten the period in between.
Disconnect the power supply:
(1) Clean and lubricate the screws, the pins, and the hinge with grease.
(2) Check the fastening points are properly tightened.
(3) Make the wire connection are in good condition.
Connect the power supply:
(1) Check the power adjustments.
(2) Check the function of the manual release.
(3) Check the function of photocells or other safety devise.
F- MAINTENANCE
Channels
4
Frequency / Transmitted max. power
433.92 MHz / power < 10mW
Power supply
2 batteries lithium CR2016 included
Security
rolling code technology
Photocells
Remote controls
Detection Method
infrared beam
Sensing Range
MAX~10m
Input Voltage
AC/DC 12~24V
Response Time
< 100ms
Operation Indicator
RX : Red LED On (beam broken) / Off (beam
aligned) TX : Red LED On
Dimensions
63 x 63 x 30 mm
Output Method
relay Output
Summary of Contents for MBA0051