10
SECTION 6. Lockers
(cont.)
Setting and Attaching Lockers: (cont.)
Shim and level lockers front to back and left to right. Ensure door reveal is consistent. Shim lockers to
obtain correct door alignment. See illustrations below.
Note:
Stretching and compressing lockers is a sign of overtightening screws which will prevent proper
functioning of lockers.
Correct Door Alignment
Doors Unaligned Left
Shim Side
To correct doors that are out
of alignment on the left,
shim on the right side of the
locker.
Doors Unaligned Right
To correct doors that are out
of alignment on the right, shim
on the left side of the locker.
Shim Side
Note:
Place shims where frames meet. DO NOT shim directly under the door as this may cause improper
functioning of the door.
Attach lockers to the wall using a minimum of one screw every 24” at the top and at the base using
3/4"
stainless steel torx head screws
provided. Pre-drill
3/16
” hole, approximately 3” down and 3” over. Do
not overtighten the screws.
Attach lockers to the base (if supplied) at the front. Secure using the 1-1/2” torx head fasteners provided.
Once the lockers are attached to the wall and base, check locker door functionality to ensure doors are
operating correctly.