Operation
Operation
-
-
Harvest
Harvest
•
Eclipse features Cold Temperature Harvest
– Condensing Unit may be located outside
•
Temperature Range between -20 and 120 F.
•
Receiver is with the condensing unit
•
Vapor line connects discharge gas and receiver vapor to
vapor inlet line in ice making section
•
High vapor flow rates achieved with no compressor
impact due to use of CPR valve
•
Vapor contains latent heat - even at sub-zero
temperatures
•
Condensing vapor in the evaporators transfers the heat
•
Evaporators warm up and ice is released