Service Diagnosis
Service Diagnosis
•
What happens if?
•
There is a refrigerant leak
– No change until refrigerant level drops below the
operational threshold for the ambient
•
Headmaster will try to maintain minimum discharge
pressure - but will be hissing as gas flows through
•
Ice formation will be poor
•
Low capacity/long freeze cycle will result
– Add charge to confirm, if ice making resumes with
normal discharge pressure there is a leak