Service Diagnosis
Service Diagnosis
•
What happened if?
•
The controller is showing a two blink refrigeration
diagnostic light
– This indicates that the ice harvest was very slow and
the controller timed-out on maximum harvest time
– Ice was NOT sensed by the control system
– Likely causes include
•
Freeze up
•
Vapor inlet valve did not open
•
Ice sensor can’t “see” ice well