Control Switches
There is a front on and off switch, located in the top
center of the louvers. Switching this switch Off will
immediately stop the machine. Switching it back on
will cause the machine to start in a timed harvest
cycle.
The controller also has on and off switches, which
can also switch the machine on and off, but their
operation is different:
To switch the machine OFF, push and release the
Off button. The machine will shut off at the end of
the next cycle. To shut the machine off
immediately, push and hold the Off button for 3
seconds.
To switch the machine ON, push and release the
On button. The machine will go through a start up
process and then resume ice making.
Note: Front On/Off Switch discontinued February
2012
February 2012
Page 12
CU1526, CU2026, CU3030
Service Manual
Note: A Component Indicator Light switches ON to
indicate that the component is operating.
Note: There are two Curtain Switch lights, SW1 and
SW2. These single plate models have one curtain
switch light on all the time, as a curtain switch light
is ON when a curtain is either open or not present.
Manual
Harvest
Clean
Code
Display
Component Operation Indicator Lights
Code
Description
. . . . . . . . . . Freeze Cycle
flashes . . . . Freeze Cycle is Pending
. . . . . . . . . . Harvest Cycle
flashes . . . . Manual Harvest
. . . . . . . . . . Bin is Full
. . . . . . . . . . Clean Cycle
. . . . . . . . . . Board Locked
. . . . . . . . . . Test Mode
. . . . . . . . . . Off
. . . . . . . . . . Self Test Failed
flashes. . . . Max Freeze - Retrying
. . . . . . . . . . . Max Freeze Time Shut Down
flashes . . . . Max Harvest - Retrying
. . . . . . . . . . Max Harvest Time Shut Down
. . . . . . . . . . Slow Water Fill
. . . . . . . . . . High Discharge Temp
. . . . . . . . . . Sump Temp Sensor Failure
. . . . . . . . . . Discharge Temp Sensor Failure
flashes . . . Short Freeze - Retrying
Short Freeze - Thin ice
- Unit Remotely
Locked Out - Contact Leasing Company
F
F
H
H
b
C
L
d
O
E
1
1
2
2
3
4
5
7
8
8 . . . . . . . . . . . .
All 4 Upper Lights Flashing
Control Operation - See Manual
Water Light On
De-Scale Light On
Flush Setting
Test Mode
Recall Diagnostic Codes
Reset from Code 1, 2, 4 or 8
- Restore water supply to
machine.
- Clean and sanitize
machine.
- To Change: Depress Off
for 3 seconds. Press On to select purge
(1-5) setting or A for Automatic.
- Depress Off for 3 seconds,
then depress Clean for 3 seconds.
- Depress Off
for 3 seconds. Press Harvest repeatedly
to go from most recent to oldest of 10.
- Depress
Off then Depress On.
Technician Section
02-4302-01
On
Off
Power
Status
De-scale
Water
Sanitize