CU1526, CU2026, CU3030
Service Manual
Wiring Diagram, CU1526 and CU2026 50 Hz after Serial Number 12021320013437
February 2012
Page 50
FUSE (3A)
O
FUSE (3A)
GN
*
*
TR
AN
SF
OR
ME
R
5
4
2
1
9
7
6
10
LINE
LOAD
12
V
230V
BK
BK
W
BN/W
W
Y
W
FAN CYCLING PRESSURE SWITCH (A/C ONLY)
HARVEST
ASSIST
SOLENOID 1
ICE THICKNESS PROBE
CURTAIN SWITCH 1
CURT
AIN SW
ITCH
J6
1
2
3
4
CAUT
ION:
PT
CR W
ILL
BE
HO
T.
COMP
RESS
OR
MA
Y NO
T ST
ART IF
PTCR
IS
NO
T AL
LOWE
D TO
CO
OL
MOT FAN
(WHEN 2ND FAN IS PRESENT)
W/Y
(AC ONLY)
(WATER COOLED ONLY)
(AIR COOLED ONLY)
FAN MOTOR
Y
HIGH PRESSURE CONTROL (WC ONLY)
L1
T1
L2
T2
CONTACTOR
MOT PUMP
SOLENOID
SOLENOID
HOT GAS
WATER
USE CO
PPER
CO
NDU
CTO
RS ON
LY
THI
S U
NIT
MU
ST
BE G
ROUN
DED.
CAUT
ION:
MORE
TH
AN
ONE
DISC
ONNE
CT M
EAN
S M
AY B
E
REQU
IRED
TO
DI
SCON
NECT
AL
L P
OWE
R T
O TH
IS U
NIT
.
17-33
74-01
RUN CAP
PTCR
POWER SUPPLY
SEE NAMEPLATE FOR PROPER VOLTAGE REQUIREMENTS AND MAXIMUM FUSE SIZE
L1
L2
LINE
12V
TRANSFORMER
HOT GA
S VALVE
WATER VALVE
CONTACTOR
COIL
COMPRESSOR
RUN CAP
WATER PUMP
PTCR
CONTAC
TOR T1
WATER LEVEL SENSOR
SUMP TEMP.
DISCHARGE TEMP.
EL
EC
TR
ON
IC
C
ON
TR
OL
BN
W
BU
W
BK
W
R/W
V
BN/W
BK
W
ELECTRONIC CONTROL
BK
R
W/R
W/R
W
DUMP VALVE
BK
DUMP VALVE
HIGH PRESSURE CONTROL
MOT FAN
W
BN
4
3
2
1
J1
3
2
1 J9
7
6
5
4
3
2
1
J2
2
1
J8
2
1
J7
R
8
FAN CYCLING PRESSURE CONTROL SWITCH (
AIR COOLED ONLY)
BN
DISCHARGE TEMP. SENSOR
SUMP TEMP. SENSOR
WATER LEVEL SENSOR
W
BK
R
EARTH G
ROUND
J10
HARV A
SSIST
SOLENOID
ICE THICKNESS PROBE
BK
W
GN/Y
GN/Y
.33 uF
Y
C
S
R
START WI
NDING
RUN WINDING
BK
W
R
BK
EXTE
RNAL
PROT
ECTO
R
CO
MP
RE
SSOR