FOR THE PLUMBER
The recommended water supply line is a 3/8-inch
O.D. copper tubing with a minimum operating
pressure of 20 PSIG and a maximum of 80 PSIG.
Connect to cold water supply line with standard
plumbing fittings, with shut off valve installed in an
accessible place between the water supply and
the cuber. ln some cases a plumber will be
required.
Water Limitations:
An ice machine is a food manufacturing plant, it
takes in a raw material, water, and turns it into a
food product, ice. The purity of the water is very
important in obtaining pure ice and in maximizing
product life. It is generally better to filter the water,
although there is no one filter that will cure all
water problems. A good filter combined with a
polyphosphate feeder gives about the best overall
performance.
DRAIN
Connections: All drains are gravity type and must
have a minimum of 1/4-inch fall per foot on
horizontal runs. The drains to be installed to
conform with the local plumbing code. Install a
vertical open vent on drain line high point to insure
good draining. The ideal drain receptacle is a
trapped and vented floor drain. Recommended bin
drain is 5/8 inch O.D. copper tubing and should be
vented and run separately. Insulation for high
humidity areas is recommended.
The ice machine sump drain is 3/4" FPT. There
must be a vent at this connection for proper sump
draining.
WATER SUPPLY AND DRAIN CONNECTION
AIR GAP BETWEEN
DRAIN LINES AND
BUILDING DRAIN
BIN
DRAIN
VENT
3/8" MALE FLARE
SUMP DRAIN MUST
BE VENTED
OPTIONAL
FILTER
POTABLE
WATER
SUPPLY
HAND
SHUT OFF
VALVE
3/4" FPT
CMS1402R