difference is below:
“Set up” mode
: the user have rights (need input password 8888) to set or
modified each parameter.
“Operation” mode
: the user haven’t right (don’t need input password) to
set or modified each parameter. User can operate according stored
parameter only.
(III) Description of parameter settings
1.
Preheating section
: when you start the program, the top heater will enter
the process, the slope of it is 3 degrees per second, when it reaches to
165
℃
(the temperature setting of preheating section), keep this
temperature for 30 sections (the time setting of preheating section, till now,
the preheating is finished, then the top heater will enter the next work
process—insulation section.
The bottom heater start to heat from room temperature, the heating slope
is 3 degrees per second, when it reaches to 165
℃
(the temperature
setting of preheating section), keep this temperature for 30 seconds (the
time setting of preheating section, till now, the preheating section is
finished, then the top heater will enter the next work process—insulation
section.
IR preheating
: Set 180
℃
, it means that the IR heating plate will be heated
to 180
℃
, and then keep it.
2.
Insulation section
: the slope of the top heater is 3degrees per second,
start from 165
℃
to 195
℃
, then keep it for 30seconds.
3.
Heating section
: the slope of the top heater is 3 degrees per second, start
from 195
℃
to 225
℃
, then keep it for 30 seconds.
The slope of the bottom heater is 3 degrees per second, start from 190
℃
to 225
℃
, then keep it for 30 seconds.
4.
Welding 1
、
welding2 and cooling section
are same as above.
The process of actual temperature control of this system can be less than
maximum control section (6 sections). During the heating process, if you
do not use the control section, then you can set 0 to close it.
6. Operation Basic Introduction
(I) De-soldering process
1. Work flow: