16
Maintenance
User Manual
SKOPE Centaur Series
To clean the condenser coil on horizontal cabinets
To clean the condenser coil on vertical cabinets
1. Isolate the cabinet from the power supply by unplugging it from the wall.
2. Open the unit front cover (usually located on the LH side of cabinet) to gain
access to the condenser filter and coil.
Note:
On model BC070-CB, the condenser coil is located at the rear of the
cabinet. Pull the cabinet out so access is available at the rear of the cabinet,
and unscrew the condenser coil cover to access the coil.
3. If fitted, remove the condenser filter by sliding it up, and remove all dust and
fluff from the filter.
4. Brush the condenser coil in the directions of the fins to remove all dust and
fluff.
5. Refit the condenser filter, close the unit front cover and reconnect the cabinet
to the power supply.
1. Isolate the cabinet from the power supply by unplugging it from the wall.
2. Swing the top panel (above the door/s) out to gain access to the condenser
coil.
3. Brush the condenser coil in the directions of the fins to remove all dust and
fluff.
4. Close the top panel and reconnect the cabinet to the power supply.
CAUTION
Unplug the cabinet from the mains power supply before
cleaning the condenser coil or washing the cabinet with water.