SciQuip Oven-140HT User Manual Download Page 2

 

 

  

 

 

 

 

 

 

 

 

 

 

SciQuip   blast air oven  has achieved good reputation and trust among various  

clients for its advanced temperature controlling technology, sound framework design,  

excellent exterior moulding and outstanding professional workmanship. This products have  

been continuously exported to the dominant companies in Europe, America and East Asia. 

Blast Air Oven applies dry heat to stopping microorganism oxygenation and protein  

denaturation, affecting electrolyte concentration, hence, killing the residual microorganism  

in some time. 

The Blast Air Oven is widely used in the field of biochemistry, chemical pharmacy, medical  

sanitation, agriculture and environment protection, etc. It is an ideal equipment for thermal  

denaturation and induration  of specimens, and the drying, sterilization, baking operations of  

specimens like food, electronic components, building material, etc.  

SciQuip” thank you for your trust in its product! 

     Since the date of your purchase of this product, after-sale service will always be with you.  

No matter what questions you meet in your using, please do not hesitate to contact us  

whenever you want. 

 

 

 

 

 
 
 
 
 
 
 
 

 

Safety instruction! 

Thanks! 

Thank you very much for your purchase of our Oven-HT series blast air  
oven  of which is specially designed for you. Your choice indicates  
that you have very high requirement on style and performance of automatic 
blast air oven.

 

Reminder 

The manual should be read and understood thoroughly, because it  

can help you to master the operating method and feature of this high- 

tech product. Prior to operation, we strongly recommend you to read  

this manual completely so that you can master all the function to the  

utmost extent. 

Summary of Contents for Oven-140HT

Page 1: ...User s Manual This Manual applies to Oven HT series horizontal airflow from back Oven 80HT 140HT 230HT Oven HT series Blast Air Oven...

Page 2: ...ration of specimens and the drying sterilization baking operations of specimens like food electronic components building material etc SciQuip thank you for your trust in its product Since the date of...

Page 3: ...mable or explosible object inside the chamber 8 When in operation the window of the equipment has a relative high temperature so any physical contact with it should be avoided 9 To avoid burn do not f...

Page 4: ...door heavily will probably leads to the damage of the equipment 8 When in operation do not open the door indiscriminately which will affect the temperature inside 9 The exterior of equipment must be...

Page 5: ...4 5 Setting of the Control Mode 4 6 Setting of the parameter under the constant temperature control mode 5 7 Setting of the parameter under the programme control mode 7 8 Setting and Application of ot...

Page 6: ...as power cut alarm sensor failure alarm and upper and lower temperature limit exceeding alarm 7 Highly responsive thermal sensor and environmental scanning microprocessor chip 8 Three dimensional heat...

Page 7: ...ity 2 5 max temperature Display LED Alarm Enabled Timer min 1 999 Settings Digital Grids Included 2 max13 2 max17 2 max21 Grid Size mm WxD 319 330 385 405 475 485 Chamber Dimensions mm WxDxH 375 365 5...

Page 8: ...art operation and press it again to stop operation Under programme control mode press this button to start operation and press it again to keep the status hold on this button for 3 seconds to stop ope...

Page 9: ...rature Then the equipment is in the state of readiness 5 Setting of the control mode This equipment has two operating mode i e constant temperature control and programme control users can choose one a...

Page 10: ...e red TM indicator turns on Press the Time button again to display the preset timing parameter minute one decimal the red TM indicator twinkles Press the Increase or Decrease button can change the par...

Page 11: ...the setting of constant temperature control mode Below is a graph showing the relation under normal condition between time and temperature when temperature keeps increasing It can be referred to when...

Page 12: ...ramme segment 3 P SL1 The ending temperature of the slope part of the first programme segment 4 P td1 Time of temperature retaining of the temperature retaining part of the first programme segment 5 P...

Page 13: ...m enters into the temperature retaining segment the setting temperature is the ending temperature of the slope segment The ending temperature of the last slope segment is the starting temperature of n...

Page 14: ...rogram begin operation from the segment displayed on the screen and take the current real temperature as the starting temperature 6 The setting and application of the parameter Hb feedback value Param...

Page 15: ...educe to 0 indicator HOLD turns off operation begins the red operating indicator RUN turns on Under programme control mode operation of programme segment begins Simplified instruction on the setting o...

Page 16: ...button for 3 seconds screen displays CIP a second later 0 press the Increase button to input the password 4 press the Change Confirm button again screen displays the hour value press the Increase or D...

Page 17: ...ting time reaches the preset value heating output will be stopped the operating indicator turns off At this time the power control transformer is still connected to power supply so turn off the main s...

Page 18: ...3 Malfunction of heating system occurs Wait a minute and observe for a while Refer to the operating procedure and change or re set parameter Notify the manufacturer for repair service Real temperature...

Reviews: