Status
Query
Action
No Contact
Heart Rate
Reading
Are you in Heart
Rate program?
Heart Rate program requires
use of wireless chest strap
transmitter.
Yes
Are both hands
being used on grips
simultaneously?
No
Both hands must be used to
get contact heart rate reading.
No
Each wire
should have
continuity with one silver
plate. Continuity between
silver plate and opposite
end of contact grip
cable? **
Yes
Is combo
or contact
heart rate PCB
plugged securely
into upper
PCB?
Yes
Secure connection to combo or
contact heart rate PCB and
upper PCB.
No
Each wire
connected
securely to the
back of a silver
plate?
No
Secure connection to silver
plates.
No
Replace contact grip cables.
Yes
Replace combo or contact
heart rate PCB. If problem
persists, replace upper PCB.
Yes
** Move cable around when taking continuity readings.
This way if there is a short in the cable, it may be found.