5.2-46
005.050.01-EN
Block
2
Block
3
Description
Cause
Remedial action
10
00
Transmit failure:
emergency stop
Transmit failure reported; illegal
state of emergency stop switch
System restarts automatically.
Make sure emergency stop
switch on transmitter not activat-
ed.
11
00
Transmitter
failure, analog
input
Transmitter failure reported,
analog inputs active
Make sure all proportional con-
trol elements on transmitter are
in zero position.
12
00
Transmitter
failure, analog
input
Transmitter failure reported,
signal redundancy test of analog
inputs illegal result
System restarts automatically.
Diagnose transmitter in TEST
MODE.
13
N
Transmitter
failure, analog
input
Transmitter failure reported,
signal redundancy test of analog
inputs illegal result
System restarts automatically.
Diagnose transmitter in TEST
MODE.
14
01
ID programming
error
ID code and/or operating pa-
rameter settings illegal
System restarts automatically.
Make sure ID programming se-
quence is successful. Restart
the system.
14
02
Program error
Programmable logic parameter
error
System restarts automatically.
Restart the system.
17
01
Supply voltage
low
Supply voltage below 8.5 VDC
System restarts automatically.
Make sure supply voltage and
supply connections are OK.
Restart the system.