47
UHE
-
F / EIH
-
F I&O Manual
IM100205
RD: APR 2019
RL: 02C
26. BURNER & TUBE KIT ASSEMBLY CHART MODELS UHE, EIH
MODELS UHE & EIH are approved for indoor commercial / industrial non
-
residential applica-
tions. For outdoor, wet and harsh environment applications refer to models UHE
-
P / EIH
-
P and
UHE
-
S / EIH
-
S.
BEFORE INSTALLING: Check that you have the correct tube kit(s) for the burner input
60,000 x 20 ft 60,000 x 30 ft 90000 x 30 ft 90,000 x 40 ft 160,000 x 50 ft 200,000 x 60 ft 90,000 x 40 ft 160,000 x 60 ft 130,000 x 40 ft
130,000 x 50 ft
130,000 x 40 ft 160,000 x 60 ft 200,000 x 70 ft 130,000 x 50 ft 200,000 x 60 ft 160,000 x 50 ft
200,000 x 70 ft
6 ft
None
3 ft
None
None
None
None
2 ft
6 ft
TK-P620-UL TK-P030-UL TK-P330-UL TK-P020-UL TK-P163-UL TK-P230-UL TK-S020-UL TK-S230-UL TK-S620-UL
Input Btuh
Tube
Length
20'
30'
30'
20'
30'
30'
20'
30'
20'
20'
1
190
30'
1
272
30'
1
272
40'
1+
1
354
40'
1+
1
354
50'
1+
1
436
50'
Stainless Steel Combustion Tube
1+
1
436
60'
Stainless Steel Combustion Tube
1+
1
518
60'
Stainless Steel Combustion Tube
1+
1
518
70'
Stainless Steel Combustion Tube
1+
2
600
Order: TUBE KIT PART # & QUANTITY REQUIRED
STAND ALONE & PRIMARY TUBE KITS
SECONDARY TUBE KITS
160,000
200,000
Turbulator* -->
Tube Kit Part #
Approx.
Weight
(lbs)
60,000
90,000
130,000
NOTE: UHE / EIH Series Burners require 120V electrical supply
Tube Kits for models UHE & EIH have an insulated double reflector.
All tube kits include tubes, insulated reflectors, tube couplers, and hangers required for installation.
Model 60,000 x 20 ft has a 6 ft turbulator installed in a tube in the Primary Tube Kit TK-P620-UL
Tube Heaters longer than 20 feet require a Primary Kit and at least one additional Secondary Tube Kit.
- Primary Tube Kits include the flanged combustion chamber tube plus one additional tube
A Secondary Tube Kit requires a Primary Tube Kit.
- Secondary Tube Kits include steel heat exchanger tubes and turbulator if required.
* TURBULATORS:
- If a turbulator is required it is factory installed in a clearly labeled tube in the Secondary Tube Kit.
- A turbulator must always be installed in the last tube at the vent end of the heater.