19
UHE
-
F / EIH
-
F I&O Manual
IM100205
RD: APR 2019
RL: 02C
sion under the first reflector
-
mate snuggly with the first reflector
20)
Through the three circular hole in the outer reflector, clear away insulation to allow access
to the slotted holes in the inner reflector
21)
Align the slotted holes in the first and second reflectors where they overlap
-
if necessary
use a screw driver or similar tool to assist in alignment of the holes
22)
Fasten the two reflectors together using three nuts and bolts supplied
•
TIP
: To place the nut on the bolt extending down through the hole at the top of the
reflector, hold nut between thumb and finger, reach under the tube, then up and over
the far side of the tube to align the nut to the bolt protruding through the hole
23)
Repeat steps 11 to 21, assembling one section of tube and reflector at a time until the sys-
tem is complete
•
If a TURBULATOR is required in the system it is located at the VENT END
24)
Install the reflector end cap at the vent end of the system using three nuts and bolts sup-
plied
25)
ENSURE THAT THE SYSTEM IS LEVEL AND THAT ALL TUBES ARE ALIGNED –
MAKE
ADJUSTMENT AT HANGERS AS REQUIRED—WELDED SEAM OF 1st & 2nd TUBES
MUST FACE DOWN
FIGURE 10: REFLECTOR INSTALLATION
Burner End
FIGURE 11: REFLECTOR ALIGNMENT
MODEL
TURBULATOR
UHE / EIH 200
-
70
NOT REQUIRED
UHE / EIH 200
-
60
2 FT (61 cm)
UHE / EIH 160
-
60
2 FT (61 cm)
UHE / EIH 160
-
50
6FT (183 cm)
UHE / EIH 130
-
50
NOT REQUIRED
UHE / EIH 130
-
40
6 FT (183 cm)
UHE / EIH 90
-
40
NOT REQUIRED
UHE / EIH 90
-
30
3 FT (91 cm)
UHE / EIH 60
-
30
NOT REQUIRED
UHE / EIH 60
-
20
6 FT (183 cm)
TABLE 4 SYSTEM TURBULATORS
:
NOTE:
Improper location of a
turbulator can cause malfunc-
tion or damage to the heater
and will void the warranty.
Tube Heaters are supplied with the re-
quired turbulator factory installed into the
tube.
Tubes with turbulators are clearly labeled
for easy identification. Install these tubes
in the position indicated on the label, at
the vent end of the system.