Schwamborn BAS 1500E Translation Of Original Operating Manual Download Page 10

1 Important informations

EN Power trowel BAS 1500V / BAS 1500E

10

1.2 Symbols used

The following symbols are used in this

documentation:

Safety instructions

This symbol indicates warnings, prohibitions and

instructions regarding potential hazards. These

instructions must be obeyed and closely

observed.

Some of the safety instructions are

accompanied by corresponding symbols.

Additional note

This symbol indicates additional information.

1.3 Liability and warranty

Liability or warranty is excluded if:
— The instructions in the operating manual have

not been observed.

— The machine or its attachments were improperly

operated.

— The maintenance was carried out inadequately

or incorrectly.

— Specified spare parts were not used.
— The protective equipment was not used, has

been altered or was removed.

— The specified power supply ratings and sur­

rounding conditions have not been observed.

The manufacturer is not liable for any damage that

may result if the user makes any changes to the ma­

chine without the manufacturer’s permission. Any

such actions will void the warranty.

1.4 Accident prevention and safety

All laws and regulations (e.g. the valid regulations on

waste disposal), accident prevention guidelines and

generally recognised safety rules must be complied

with when working on and with the machine.

The following instructions comply with legislation, di­

rectives and publications such as:
— EU Machinery Directive
— EU Product Liability Directive
— Law governing technical materials
— Law governing equipment safety
— Law governing product liability
This operating manual is intended for operators and

tool setters, as well as for the personnel that service,

maintain and repair the machine. Together with all

the technical documentation, it is intended to help
— avoid hazardous situations
— use the machine for its intended applications
— avoid downtime and repair costs
— maintain the function of the machine
— increase the service life of the machine
The manufacturer and owner of the machine must

observe the contents and provisions of the EC direc­

tives. The effectiveness of any measure ultimately

depends on how well all parties, i.e. the manufac­

turer, the owner and the machine operators, work

together to uphold safety standards.

1.5 Safety instructions

This machine incorporates state of the art technology

and has been built in accordance with recognised

safety regulations. This ensures that the highest pos­

sible standards of occupational safety are main­

tained. However, incorrect use of the machine could

endanger personnel or cause material damage.

The machine may only be operated by people

who have been assigned to do so and who have

the appropriate training and skills!
A general inspection of the machine must be

conducted before starting up the machine! Pay

particular attention to damaged or loose compo­

nents, and to wear!

The machine may only be put into operation if it

is in perfect technical condition!
Adding to or modifying the machine in any way

that could compromise operating safety is pro­

hibited!
If any defects are found in the machine that

could endanger people or damage property,

stop the machine immediately and make sure

that it cannot be used again until all repairs have

been completed!

Warning

Prohibition

Direction

Summary of Contents for BAS 1500E

Page 1: ...BAS 1500E BAS 1500V DE Betongl ttmaschine Originalbetriebsanleitung 3 EN Power trowel Translation of the original operating manual 9...

Page 2: ...2 BAS 1500V 8 3 7 6 5 2 1 15 8 14 13 16 12 BAS 1500E 11 10 9 1 17 4...

Page 3: ...der Schwamborn Ger tebau GmbH Kein Teil dieser Originalbetriebsanleitung einschlie lich der bersetzungen der Originalbetrieb sanleitung darf in irgendeiner Form ohne schriftliche Genehmigung der Schwa...

Page 4: ...aftung Gesetz ber Technische Arbeitsmittel Gesetz ber Ger tesicherheit Gesetz ber Produkthaftung Die Betriebsanleitung ist f r den Bediener sowie f r das Personal zur Wartung Pflege und Instandset zun...

Page 5: ...werden Die zur Stromversorgung dienende Netzsteck dose muss gem den rtlichen Vorschriften versorgt und installiert sein Alle verwendeten Stecker und Kupplungen m s sen spritzwassergesch tzt sein Alle...

Page 6: ...osition un gef hr auf H fth he schwenken und die Klemmschraube festdrehen Die Maschine ist betriebsbereit 2 2 Beton abziehen verdichten Der Bediener muss die Maschine immer kontrol lieren und steuern...

Page 7: ...2 Maschine aufbewahren Die folgenden Arbeiten sollten von 2 Personen ausgef hrt werden 1 Wenn die F hrungsstange 1 montiert bleiben soll a Die Maschine an der F hrungsstange fest halten b Die Klemmsch...

Page 8: ...gel 97 dB A 82 dB A Schwingungsgesamtwert 2 5 m s2 2 5 m s2 ermittelt unter standardisierten Hersteller Betriebsbedingungen nach Messmethode HARM 6 Konformit tserkl rung Schwamborn Ger tebau GmbH Robe...

Page 9: ...E 1 Important informations Schwamborn Ger tebau GmbH Schwamborn Ger tebau GmbH reserves all rights Any reproduction use or distribution of the original operating manual or the translation of the origi...

Page 10: ...ning product liability This operating manual is intended for operators and tool setters as well as for the personnel that service maintain and repair the machine Together with all the technical docume...

Page 11: ...lectric supply should be installed and provided with mains cur rent according to local regulations All installed plugs and couplings have to be pro tected from splash water Only suitably knowledgeable...

Page 12: ...d tighten the clamping screw The machine is ready for operation 2 2 Levelling Compacting cement The operator must always be able to control and steer the machine The guide bar 1 may not be released du...

Page 13: ...perating manual 2 3 2 Storing the machine The following tasks ought to be carried out by 2 persons 1 If the guide bar 1 should remain mounted a Hold the machine at the guide bar b Loosen the clamping...

Page 14: ...rox 15 kg approx 17 5 kg Noise level 97 dB A 82 dB A Vibration total value 2 5 m s2 2 5 m s2 Determined under standardised manufacturer operating conditions according to the HARM measuring method 6 De...

Page 15: ......

Page 16: ......

Reviews: