10 Installation
AV200pro
•liquid has been spilled on the device or objects have fallen into the
device. wenn das Gerät Regen oder Wasser ausgesetzt war.
•the device has been exposed to rain or water.
•the device does not work, even though the operating instructions have
been followed properly.
•the device’s case is damaged.
2.2
Electrical installation
���
Install the AV200pro properly on the top-hat rail.
Take into account the vertical installation alignment of the device, so that the
mains power supply comes from above
���
Now connect the conductors according to the line connections.
When connecting to the sockets, make sure the conductor cross-section is
0.18 mm² to 6 mm².
•Single-phase connection: Neutral conductors and external conductors
are connected to terminals N and L1 (see Fig. 4).
•Three-phase connection: Neutral conductors and external conductors
are connected to terminals N and L1. The connection of external con-
ductors L2 and L3 is optional and intended for optimising the signal
transmission. The device is supplied with power via terminals N and L1
(see Fig. 5).