  RUBIN 

 

SAFETY  

 
 

3.2  Safety instructions for delivery / unpacking  

 

The  therapy  couches  are  100%  visually  inspected  and  checked  for  electrical  and  mechanical 
function before shipment. The couch has left the factory in perfect and operational condition. 
Remove the transport securing strap under the head section and in the frame! 
Attention when opening the packaging! Do not use pointed or sharp objects, the padding could be 
directly damaged. 
Check immediately after receipt  of the shipment for completeness of the delivery as  well as for 
packaging damage. In the event of damage, this must be claimed immediately from the carrier and 
must be noted immediately on the shipping documents. 
If damage to the medical device is detected, this must be reported in writing to Schupp GmbH & 

Co. KG within 2 working days. 
After this period, warranty claims arising from transport damage can no longer be asserted. 

3.3  Safety instructions for commissioning  

 

Treatments  may  only  be  carried  out  on  a  therapy  couch  that  is  in  perfect  condition  in  terms  of 
safety; there is no danger from electrical energy. 
The therapy couch may only be actively connected to the mains during treatment. 
The voltage and frequency of the house mains supply must correspond to the specifications on the 
type plate. Otherwise operation is prohibited. 
The stretcher has been designed exclusively for use under normal conditions indoors. 
The therapy couch should be placed on a firm and level surface with adequate free space for the 

user. 

Warning

 

Observe the acclimatisation time before commissioning. 

 

The power cable must be positioned in such a way that it does not get jammed between the moving 

parts of the couch - and - so that nobody can trip over it. Strong tensile loads as well as running 
over with the couch must be avoided. 

 

Do not fix any cables or hoses to the frame, as they can be torn off by the couch movement. 

 

The mains plug must be disconnected for all activities inside the couch. 

 

When  using  additional  devices  (e.g.  red  light  or  heat  emitters),  safety  distances  must  be  strictly 
observed. Uncontrolled adjustment may result in burns to the skin or upholstery. 

 

 

When  moving  or  lifting  the  wheeled  frame  of  the  stretcher,  no  patient  may  be  on  the  stretcher 
(overloading and danger of tipping over). 
Treatments are only allowed with the wheel frame retracted. 

Caution 

Personally keep enough distance when adjusting and driving the couch. 

 

 

Before  or  during  each  position  adjustment  of  the  couch,  make  sure  that  no  persons  or  objects 
(children, animals, chairs, stools....) are in the moving area of the couch. 
Also do not store any objects for use (e.g. covers, towels, belts, cushions....) in the area of the 
frame! 
Never load the arm, foot and/or head section with the total weight of the patient (danger of tipping 
over) - a maximum load of 30kg is permitted. 

Warning

 

Neither the therapist nor the patient may use the arm or head section as a sitting, kneeling, or  

 

Abusing the ascender. 

 
 

 

Summary of Contents for RUBIN 131435

Page 1: ...EN INSTRUCTIONS FOR USE RUBIN Therapy couches 131435 UDI RUBIN Actual instruction manual ...

Page 2: ... storage and processing in electronic systems Infringements give rise to a claim for damages and may have penal consequences All rights reserved 2022 SCHUPP GmbH Co KG Warranty Liability These instructions for use are obligatory before carefully and completely before putting the product into operation For correct use of the medical device observe all instructions and safety notes The instructions ...

Page 3: ...der 9 6 3 Height adjustment with electric motor 10 6 4 Adjustment of the headrest upholstery 1 3 parts 12 6 5 Adjustment of the arm part upholstery 3 parts 12 6 6 Adjustment of the roof kyphosis position 13 6 7 Adjustment of the footrest upholstery 13 6 8 Setting as a chair 14 6 9 Adjustment of the Trendelenburg position 14 6 10 Wheeled frame 15 6 11 Paper roll holder 15 6 12 Equipment optional as...

Page 4: ...rapy tables from SCHUPP GmbH Co KG are developed in the Black Forest Baden Württemberg and manufactured with regional suppliers The assembly of the therapy tables takes place in our ISO certified production facility and thus guarantees a high and always consistent processing quality 2 0 Safety regulations 2 1 Safety signs Symbols Safety relevant sections instructions or notes are highlighted by th...

Page 5: ... EC Medical hydraulic equipment General requirements for safety 2 3 Intended use The therapy couch of the company Schupp GmbH Co KG is a medical device of class 1 EU MDR 2017 745 and is intended exclusively for professional use by medically trained personnel and instructed users for the proper positioning and storage of patients during therapeutic healing and medical treatments or for the short te...

Page 6: ...ted and authorised in work safety and accident prevention regulations to work on the therapy couch Caution The operator must ensure that all users have read and understood the instructions warnings and safety notes in these instructions and are sufficiently informed about their operation This must be checked at regular intervals The operator must ensure that the therapy couch cannot be operated by...

Page 7: ...ion is prohibited The stretcher has been designed exclusively for use under normal conditions indoors The therapy couch should be placed on a firm and level surface with adequate free space for the user Warning Observe the acclimatisation time before commissioning The power cable must be positioned in such a way that it does not get jammed between the moving parts of the couch and so that nobody c...

Page 8: ...safety inspections according to MPBetreibV Medical Devices Operator Ordinance BetrSichV Operational Safety Ordinance and DGUV German Social Accident Insurance 4 0 Warranty Guarantee Schupp GmbH Co KG guarantees you a therapy couch free of material and processing defects The couch was thoroughly tested before shipment and 100 approved in the final production test The warranty period is 60 months on...

Page 9: ...t of the couch frame In the case of an energetically operated therapy couch it should be positioned near a power socket Lay the mains cable in such a way that there is no danger use cable bridges if necessary Check whether the operating voltage of the therapy couch label corresponds to the mains voltage The therapy couch is immediately ready for operation after connection to the mains voltage 6 2 ...

Page 10: ...utton immediately interrupts the adjustment process Manual switch Foot switch Foot switch fixed Once the height adjustment has been completed within 3 seconds before the couch switches off automatically If the interruption is greater than 3 seconds you must execute the double pressure release again For switching diagram see technical data The times are permanently coded in the drive and cannot be ...

Page 11: ...uble press release again For switching diagram see technical data The therapy couch must not be operated by unauthorised persons when unattended Children must always be supervised and are not allowed in the area of the therapy couch Cleaning and care personnel must always be instructed in occupational safety DANGER Moving parts keep your distance when adjusting the position Never use the all round...

Page 12: ...ead section may be loaded with a maximum of 30kg Warning 6 5 Adjustment of the arm part upholstery 3 parts With the 3 piece headrest optional both armrests can be adjusted completely independently of each other The respective arm sections can be swivelled sideways to the body section with the holder up to 180 In addition the armrest upholstery is rotatably mounted on the frame to ensure optimum co...

Page 13: ...sion with electric motor the roof position is realized with a hand switch or foot switch The adjustment takes place evenly and independently of the patient s weight The motor only works during permanent actuation of the corresponding switch In the end positions the movement stops automatically Watch out for hands and objects when adjusting the body part pads Position adjustment inform patient befo...

Page 14: ...ner Position adjustment inform patient beforehand and secure against slipping if necessary Do not load the foot section pad with the maximum patient weight Warning 6 9 Adjustment of the Trendelenburg position To adjust the Trendelenburg position both the head and body section and the foot section cushion must be brought into deflection The headrest is adjusted by releasing the operating lever unde...

Page 15: ...rame is designed for moving the stretcher without a patient overload For stability treatments must only be carried out with the wheel frame inactive Never extend or retract the wheel frame while a patient is on the stretcher The shock generated during lowering can cause pain and injury in sensitive patients e g with spinal disease Only operate the gearshift pedals with your feet there is a risk of...

Page 16: ...th 65 cm Pad width 80 cm imitation leather 6cm durable composite structure imitation leather 8cm Comfort de Luxe padding extra soft Head section incl nose slot adjustable with GDF 30 55 Head section 3 tgl incl nose slit adjustable with GDF 30 55 arm sections can be lowered up to 25cm and swivelled 180 Nose slit insert Headboard Pro Comfort one piece with 3 different inserts Inserts Lying surface 2...

Page 17: ... plugs arm section guides as well as operating parts for the electric height adjustment 8 0 Service life maintenance and care The therapy couch you have purchased is designed for an extremely long service life The limiting factor here is the drive which is designed for a lifetime of max 10 years or 100000 cycles After this time depending on the condition of the table the drive can be replaced by o...

Page 18: ...d or greased The piston rod of the drive should be regularly cleaned of dust with a soft cloth If the electric motor therapy couch is not used for a longer period of time it should be disconnected from the mains supply Power cable Check the power cord regularly If it is damaged it must be replaced immediately Please contact the Schupp service department for this purpose Wheeled frame To ensure smo...

Page 19: ... etc leads to damage and after a short time to brittleness and discoloration of the artificial leather surface The upholstery must not be cleaned with alcoholic or chemical solvents such as thinner petrol or similar Do not use chlorides synthetic detergents wax polishes or aerosol sprays for cleaning Warning Always disconnect the mains plug before cleaning Electrical voltage never clean the therap...

Page 20: ...ut No function of the couch drive Motor is not connected to the power supply Fuse is defective Cables are damaged Check that the couch is properly connected to a 230V socket and that this socket is live Check the fuse in the house distribution box Check the power cable for damage Check supply line of hand or foot switch for damage Check whether the connecting cables of the switching elements are c...

Page 21: ... internal protective device can switch off the drive when the couch is under maximum load Wait until the drive has cooled down again Problem cannot be fixed Unknown Contact the Schupp service department see last page Be sure to pay attention to the following features of your therapy couch Type part number Serial number This data can be found on the type plate on the frame of the foot section end o...

Page 22: ...r disposed of in a manner that is safe for people and the environment Please inform yourself in principle about the regulations applicable in your country or also about the local regulations for the disposal of old devices and accessories Watch out for physical hazards such as sharp edges during disassembly disposal 12 0 Technical data Medical Devices smashing EU MDR Class 1 medical device Dimensi...

Page 23: ...surface Static load Lifting cylinder electric motor Max 200kg 131435 Adjustment range Roof kyphosis position Adjustment range 0 25 Weight 3 piece 105 kg without optional equipment 5 piece 110 kg without special equipment Wheels Frame Ground clearance Load capacity roll 20 mm double swivel castors on head and foot section side 70kg Accessibility YES but not in version with fixed foot switches on bo...

Page 24: ...A1 2011 AC 2012 EN 61000 6 4 2007 A1 2011 EN55014 CISPR 14 Noise Emission Security tested according to HANNING CE conformity as proof of compliance with electrical safety in accordance with the following standard EN 60601 1 2006 AC2010 A1 2013 EN 60601 1 2 2007 AC2010 ANSI AAMI ES60601 1 2008 3rd edition CAN CSA 22 2 No 60601 1 2008 Noise Emission 50 dB A DIN EN ISO 3746 2011 03 Application climat...

Page 25: ...witch off t3 Share Drive Timing diagram Time min s max s Explanation t1 0 3 1 5 t1 Switch on time at first pressure Switching unit t2 0 3 2 t2 Waiting time until second pressure switching unit t3 3 Waiting time until the enable is switched off If the maximum times are exceeded or t1 and t2 are not reached the release procedure at START starts again START no release Switching element with single Ma...

Page 26: ...220822 SCHUPP GmbH Co KG 72280 Dornstetten Aach Glattal Straße 78 T 49 0 7443 243 0 F 49 0 7443 243 255 info schupp gmbh de www schupp shop 26 RUBIN DECLARATION OF CONFORMITY E ...

Page 27: ...220822 SCHUPP GmbH Co KG 72280 Dornstetten Aach Glattal Straße 78 T 49 0 7443 243 0 F 49 0 7443 243 255 info schupp gmbh de www schupp shop 27 ...

Page 28: ...220822 SCHUPP GmbH Co KG 72280 Dornstetten Aach Glattal Straße 78 T 49 0 7443 243 0 F 49 0 7443 243 255 info schupp gmbh de www schupp shop 28 RUBIN DECLARATION OF CONFORMITY H ...

Page 29: ...ne 49 0 7443 243 399 Fax 49 0 7443 243 255 Email vertrieb schupp gmbh de Internet www schupp shop You can reach our CH REP under CHRN AR 20002650 DORER GmbH Lörracherstrasse 50 4125 Riehen Phone 41 0 79 6371094 Email Thomas dorer dorer gmbh com Visit us on site Schupp GmbH Co KG Glattal Street 78 72280 Dornstetten Head office Production of preparations and personal care products Schupp GmbH Co KG ...

Reviews: