TECHNICAL DATA
12.1 Switching diagrams - Enable coding
Share
START
RELEASE
with double
Switching element
Click
Manual pushbutton
Foot switch
1
Railing
0
t1
t2
Motor
Move
Waiting time
until switch off
t3
Share
Drive
Timing diagram
Time
min (s)
max (s)
Explanation:
t1
0,3
1,5
t1 = Switch-on time at first pressure Switching unit
t2
0,3
2
t2 = Waiting time until second pressure switching
unit
t3
3
Waiting time until the enable is switched off
If the maximum times are exceeded or t1 and t2 are not reached, the release procedure at
START
starts again.
START
no release
Switching element
with single
Manual pushbutton
Click
Foot switch
1
Railing
0
t1 > t1max
Motor
Move
Waiting time
until switch off
Share
Drive
13.0 Declaration of Conformity