Assembly
Air bleed screw for the piston chamber
When connecting the quick-change pallet systems, it is important
to note that the piston chamber can only be ventilated via the air
connections during the locking process. The relevant valves or
shut-off valves should therefore be equipped with load relief.
This also applies to the turbo connection.
If the turbo connection
is not used, the relevant side of the piston must have a way of
being ventilated.
This is optimally done via the turbo connection
itself.
For the NSE3-A3 138, a ventilation option for the cylinder chamber
can be created by removing the M4 x 4 set-screw in the cover of
the clamping module. The following views illustrate the ventilation
options.
Air bleed screw for applications without turbo
Air bleeding and ventilation via turbo connection
hose-free
direct
connection for
turbo function
Air bleeding and ventilation via the cover and open
ventilation channel in the installation space
Caution: The set-screw in the cover must
be removed for air bleeding and ventilation
Ensure air bleeding and
ventilation via open recess
Connection for blow-out / air purge
The air connection for the blow-out air / air purge is achieved via
the bottom M7 connection thread by installation of a screw-in
union. Alternatively, the air supply can be actuated from a channel
bore hole leading out of the installation location of the clamping
module. To do this, a channel bore with seal seat must be installed
in the installation space. To seal this, the enclosed O-ring Ø 6 x 5.5
must be inserted in the seal seat.
Direct connection from installation space
with seal to cone seal via O-ring Ø6 x 5.5
(scope of delivery KVS3 138)
Air flow for blow-out
function (max. 2 bar)
Sealing of the installation s
pace with O-ring
recommended (scope of
delivery KVS3 138)
Air outlets with closed quick-change pallet module
21