Assembly
20
05.00 | NSE-A3 | VERO-S quick-change pallet system | en | 1376941
CAUTION
Danger of injury due to sharp edges and rough or slippery
surfaces
•
Wear personal protective equipment, particularly protective
gloves.
1. Check the flatness of the bolting surface.
2. Screw the module with the O-rings inserted onto the clamping
station.
✓
Observe permissible tightening torques for the mounting
screws and the strength class.
}
4 [
/
000]
.
✓
via the hose-free direction connection in the base of the
quick-change pallet system, OR
✓
via supply lines on the side G1/8" connections
– remove locking screws G1/8".– screw in air
connections.
4. If necessary, connect monitoring functions.
5.3 Fastening and connection
Flatness
If several linked clamping modules are mounted, make sure that
the flatness and height deviation of the outer ring locating
surfaces from clamping module to clamping module (with respect
to a 200 mm gauge) is ≤ 0.03 mm. The gauge deviation may not
exceed ± 0.015 mm.
Redundancy
Due to redundancy, a clamping pin with positioning accuracy in
one direction (SPB 40, sword-shaped position) must be used for
clamping modules that are more than 160 mm apart or that do not
exhibit a positioning tolerance of ± 0.01 mm. The sword-shaped
alignment surfaces on the SPB 40 clamping pin must be aligned at
right angles to the longitudinal axis between clamping pins SPA 40
and SPB 40. This allows for compensation of a distance offset
between the clamping areas to be aligned. For the clamping areas
that are not intended for aligning the device or pallet, clamping
pins with centering clearance (SPC 40) must be used (also refer to
chapter "Clamping pins"
).