Maintenance
26
03.00 | TCU-P | Assembly and Operating Manual | en | 389462
6.4.2 Variant without locking (OV)
Position of the item numbers
WARNING
Risk of injury due to unexpected movements!
If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause
serious injuries.
•
Before starting any work on the product: Switch off the power
supply and secure against restarting.
•
Make sure, that no residual energy remains in the system.
Ø
Detach cable connections.
Ø
Remove compressed air lines.
Ø
Remove product from handling device.
NOTE
Housing-top (22) and adapter plate are aligned to each other,
using centering sleeves (50).
Ø
Remove screws (51) and separate product form the adapter
plate.
Ø
Remove screws (52) from the housing-top (02).
Ø
Remove screws (53) and remove bolt (09).
Ø
Separate housing top (22) from flange bottom (01).
Ø
Remove screws (52) from the flange-bottom (01) and replace
eleastomer (15/16).
6.5 Drawings
The following figures are example images.
They serve for illustration and assignment of the spare parts.
Variations are possible depending on size and variant.