Assembly and connection
26
05.00 | KSF3, KSF3-LH, KSF3-F | TANDEM Clamping Force Block | en | 1467140
5.2.4 Pneumatic circuit diagram
3/2 directional
control valve
Circuit symbols
5/3 directional control
valve,
center position ventilated
Pressure switch
Actuation
Pressure gauge
Flow control valve
Compressed air supply
<-- -->
Jaw stroke "open"
--> <--
Jaw stroke "close"
1
Dynamic pressure monitoring for jaw end position "open" (2 bar)
2
Air coupling in top jaw 1
3
Air coupling in top jaw 2
4
Dynamic pressure monitoring jaw stroke "closed" (2 bar)